VDC Sensor Midpoint Setting Mode
After installing, replacing or adjusting the following parts, perform the VDC sensor midpoint setting mode.
- Steering angle sensor
- Steering wheel
- Suspension parts
- Wheel alignment
- VDCCM&H/U
- VDCCM&H/U bracket
- Park the vehicle on a level surface, and set the steering wheel to the neutral position.
- Perform the VDC sensor 0 point setting mode.
- Connect the Subaru Select Monitor.NOTE: For detailed operation procedures, refer to "Application help"
- Turn the ignition switch to ON.
- On [Start] display, select [Diagnosis].
- On Vehicle selection display, input the target vehicle information and select [OK].
- On Main Menu display, select [Each System].
- On [Select System] display, select [Brake Control], and then select [Next].
- On [Select Function] display, select [Data Monitor].
- From the data monitor item list, select [Steering Angle Sensor], [Longitudinal G Sensor] and [Abnormal Lateral G Sensor output].
- Check that the steering angle sensor output value is between -10 and 10 deg.NOTE: If the output value is different from the standard value, check the steering wheel.
- Check that output values for the longitudinal G sensor and lateral G sensor are -2 - 2 m/s2.NOTE: If the output value is not at the standard value, check the installing condition of the VDCCM&H/U and VDCCM&H/U bracket.
- On [Select Function] display, select Work Support.
- From the work support item list, select [VSC(VDC) Centering Mode], and perform the setting according to the procedure displayed on the Subaru Select Monitor screen.
- Connect the Subaru Select Monitor.
- Drive the vehicle for 10 minutes, and check that there is no system malfunction or the warning light illumination while driving.
- Make sure that the DTC is not stored.