Power Rear Gate Control Module

Fig 1: Identifying Power Rear Gate Control Module Connector Terminals
G09485132Courtesy of SUBARU OF AMERICA, INC.
Terminal No. (terminal symbol) Item Measuring condition Standard
(R422) No. 1 (+B) ←→ Chassis ground Voltage Always 10.5 - 16 V
(R422) No. 2 (SW-V) ←→ Chassis ground Voltage Always 10.5 - 16 V
(R422) No. 3 (CLUTCH (GND)) ←→ Chassis ground Resistance Always Less than 1 Ω
(R422) No. 4 (SOL (-)) ←→ Chassis ground Voltage During solenoid cancellation output Less than 1 V
(R422) No. 5 (CLOSER (OPEN)) ←→ Chassis ground Voltage When power rear gate auto closer is performing the release operation 10.5 - 16 V
(R422) No. 6 (SOL (COMMON)) ←→ Chassis ground Voltage Always 10.5 - 16 V
(R422) No. 7 (MOTOR (CLOSE)) ←→ Chassis ground Voltage When auto-close is in operation 10.5 - 16 V
(R422) No. 8 (+POWER B) ←→ Chassis ground Voltage Always 10.5 - 16 V
(R422) No. 9 (SEN-V) ←→ Chassis ground Voltage Always 4 - 6 V
(R422) No. 10 (IGN) ←→ Chassis ground Voltage When ignition switch is ON 10.5 - 16 V
(R422) No. 11 (CLUTCH (+)) ←→ Chassis ground Voltage When auto-close is in operation 10.5 - 16 V
(R422) No. 12 (SOL (BUZZER)) ←→ Chassis ground Resistance When buzzer is OFF Less than 1 Ω
(R422) No. 13 (CLOSER (CLOSE)) ←→ Chassis ground Voltage When power rear gate auto closer is in pull-in operation 10.5 - 16 V
(R422) No. 14 (P-GND) ←→ Chassis ground Resistance Always Less than 1 Ω
(R422) No. 15 (MOTOR (OPEN)) ←→ Chassis ground Voltage When auto-open is in operation 10.5 - 16 V
(R422) No. 16 (SOL (+)) ←→ Chassis ground Voltage When solenoid lock is output Less than 1 V
(R423) No. 1 (LIN) ←→ Chassis ground - Cannot be measured (LIN communication line) -
(R423) No. 2 (HALF STOP SW) ←→ Chassis ground Voltage When memory height switch is ON 10.5 - 16 V
(R423) No. 3 (SOL POS SW) ←→ Chassis ground Voltage Except for PRG at half-stop state 4 - 6 V
(R423) No. 4 (SECTOR SW) ←→ Chassis ground Voltage When PRG is fully closed Less than 1 V
(R423) No. 5 (-) ←→ Chassis ground - - -
(R423) No. 6 (GATE SW) ←→ Chassis ground Voltage When PRG inner SW is ON 10.5 - 16 V
(R423) No. 7 (-) ←→ Chassis ground - - -
(R423) No. 8 (S-GND) ←→ Chassis ground Resistance Always Less than 1 Ω
(R423) No. 9 (-) ←→ Chassis ground - - -
(R423) No. 10 (SEN-A) ←→ Chassis ground Voltage When PRG is stopped 4 - 6 V
(R423) No. 11 (T-SEN R) ←→ Chassis ground Voltage When sensor is ON Less than 1 V
(R423) No. 12 (T SEN L) ←→ Chassis ground Voltage When sensor is ON Less than 1 V
(R423) No. 13 (LATCH SW) ←→ Chassis ground Voltage When PRG is fully closed 4 - 6 V
(R423) No. 14 (COURTESY SW) ←→ Chassis ground Voltage When PRG is fully closed 4 - 6 V
(R423) No. 15 (HAZARD) ←→ Chassis ground Voltage When hazard switch is OFF Less than 1 V
(R423) No. 16 (D SW) ←→ Chassis ground Voltage When driver's switch is ON 10.5 - 16 V
(R423) No. 17 (-) ←→ Chassis ground - - -
(R423) No. 18 (T-SEN GND) ←→ Chassis ground Resistance Always Less than 1 Ω
(R423) No. 19 (SEN-GND) ←→ Chassis ground Resistance Always Less than 1 Ω
(R423) No. 20 (SEN-B) ←→ Chassis ground Voltage When PRG is stopped 4 - 6 V