Multi Function Display
- Standard type
| Terminal No. | Item | Measuring condition | Standard |
|---|---|---|---|
| 1 (+B) ←→ Chassis ground | Voltage | Always | 10 - 14 V |
| 2 (GND) ←→ Chassis ground | Resistance | Always | Less than 1 Ω |
| 3 (IG) ←→ Chassis ground | Voltage | IG OFF → ON | 0 V → 10 - 14 V |
| 9 (U-ART com.) | - | Cannot be measured | - |
| 10 ←→ Chassis ground | Voltage | Passenger's airbag ON indicator light OFF → ON | 0 V → 1.5 V |
| 11 ←→ Chassis ground | Voltage | Passenger's airbag OFF indicator light OFF → ON | 0 V → 1.5 V |
- High grade type
Refer to the "Control Module I/O Signal" of the "MULTI-FUNCTION DISPLAY(DIAGNOSTICS)" section.
Ref. to MULTI-FUNCTION DISPLAY(DIAGNOSTICS)>Control Module I/O Signal>ELECTRICAL SPECIFICATION .