Communication For Initializing Impossible
Detecting condition:
- Defective harness connector
- Power supply circuit malfunction
- Defective combination meter
- Defective CAN communication circuit
- Defective Subaru Select Monitor
Trouble symptom:
Communication is impossible between combination meter and Subaru Select Monitor.
Wiring diagram:
NOTE:
For the coupling connector, refer to "WIRING SYSTEM".
- Combination meter system Ref. to WIRING DIAGRAM , Combination Meter System.
- CAN communication system Ref. to WIRING DIAGRAM CAN Communication System.
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK FUSE. Check the fuse. |
Is the check result OK? | Go to step 2 . | Replace the fuse. If the replaced fuse blows out easily, repair the ground short circuit in the harness between the battery and combination meter. |
2 CHECK HARNESS.
|
Is the voltage 10 - 13 V? | Go to step 3 . | Repair the open circuit of harness between combination meter connector and fuse. |
| 3 CHECK HARNESS Use a tester to measure the resistance between the combination meter connector and chassis ground. Connector & terminal (i10) No. 20 - Chassis ground: (i10) No. 40 - Chassis ground: |
Is the resistance less than 1 Ω? | Go to step 4 . | Repair the open circuit of harness between combination meter connector and chassis ground. |
| 4 CHECK LAN SYSTEM. Inspect LAN system. Ref. to BASIC DIAGNOSTIC PROCEDURE . |
Is the check result OK? | Go to step 5 . | Perform the inspection according to the diagnosis for LAN system. |
5 CHECK COMBINATION METER.
|
Is communication possible? | The circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis.
NOTE:
In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
|
Replace the combination meter. Ref. to COMBINATION METER . |