Execution Condition
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | More than 10.9 V |
| Main feedback | In operation |
| Rear oxygen sensor voltage when fuel cut ends (Fuel cut elapsed time Fuel shut-off function thereafter) | Less than 0.15V 3000ms or more Not in operation |
| Estimated element temperature of rear oxygen sensor when fuel cut has completed | 500°C (932°F) or more |
| Amount of intake air | 18g/s (0.63oz/s) or more |