LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Subaru >> 2018 >> Forester 2.0XT Touring >> Repair and Diagnosis (Single Page) >> Body & Frame >> Exterior Body Panels >> Power Rear Gate System (Diagnostics) >> Control Module I/O Signal >> Electrical Specification >> Power Rear Gate Control Module
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Power Rear Gate Control Module

G12518930Courtesy of SUBARU OF AMERICA, INC.
Terminal No. (terminal symbol) Item Measuring condition Standard
(R422) No. 1 (+B)↔ Chassis ground Voltage Always 10.5 - 16 V
(R422) No. 2 (SW-V)↔ Chassis ground Voltage Always 10.5 - 16 V
(R422) No. 3 (CLUTCH (GND))↔ Chassis ground Resistance Always Less than 1 Ω
(R422) No. 4 (SOL (-))↔ Chassis ground Voltage During solenoid cancellation output Less than 1 V
(R422) No. 5 (CLOSER (OPEN))↔ Chassis ground Voltage When power rear gate auto closer is performing the release operation 10.5 - 16 V
(R422) No. 6 (SOL (COMMON))↔ Chassis ground Voltage Always 10.5 - 16 V
(R422) No. 7 (MOTOR (CLOSE))↔ Chassis ground Voltage When auto-close is in operation 10.5 - 16 V
(R422) No. 8 (+POWER B)↔ Chassis ground Voltage Always 10.5 - 16 V
(R422) No. 9 (SEN-V)↔ Chassis ground Voltage Always 4 - 6 V
(R422) No. 10 (IGN)↔ Chassis ground Voltage When ignition switch is ON 10.5 - 16 V
(R422) No. 11 (CLUTCH (+))↔ Chassis ground Voltage When auto-close is in operation 10.5 - 16 V
(R422) No. 12 (SOL (BUZZER))↔ Chassis ground Resistance When buzzer is OFF Less than 1 Ω
(R422) No. 13 (CLOSER (CLOSE))↔ Chassis ground Voltage When power rear gate auto closer is in pull-in operation 10.5 - 16 V
(R422) No. 14 (P-GND)↔ Chassis ground Resistance Always Less than 1 Ω
(R422) No. 15 (MOTOR (OPEN))↔ Chassis ground Voltage When auto-open is in operation 10.5 - 16 V
(R422) No. 16 (SOL (+))↔ Chassis ground Voltage When solenoid lock is output Less than 1 V
(R423) No. 1 (LIN)↔ Chassis ground - Cannot be measured (LIN communication line) -
(R423) No. 2 (HALF STOP SW)↔ Chassis ground Voltage When memory height switch is ON 10.5 - 16 V
(R423) No. 3 (SOL POS SW)↔ Chassis ground Voltage Except for PRG at half-stop state 4 - 6 V
(R423) No. 4 (SECTOR SW)↔ Chassis ground Voltage When PRG is fully closed Less than 1 V
(R423) No. 5 (-)↔ Chassis ground - - -
(R423) No. 6 (GATE SW)↔ Chassis ground Voltage When PRG inner SW is ON 10.5 - 16 V
(R423) No. 7 (-)↔ Chassis ground - - -
(R423) No. 8 (S-GND)↔ Chassis ground Resistance Always Less than 1 Ω
(R423) No. 9 (-)↔ Chassis ground - - -
(R423) No. 10 (SEN-A)↔ Chassis ground Voltage When PRG is stopped 4 - 6 V
(R423) No. 11 (T-SEN R)↔ Chassis ground Voltage When sensor is ON Less than 1 V
(R423) No. 12 (T SEN L)↔ Chassis ground Voltage When sensor is ON Less than 1 V
(R423) No. 13 (LATCH SW)↔ Chassis ground Voltage When PRG is fully closed 4 - 6 V
(R423) No. 14 (COURTESY SW)↔ Chassis ground Voltage When PRG is fully closed 4 - 6 V
(R423) No. 15 (HAZARD)↔ Chassis ground Voltage When hazard switch is OFF Less than 1 V
(R423) No. 16 (D SW)↔ Chassis ground Voltage When driver's switch is ON 10.5 - 16 V
(R423) No. 17 (-)↔ Chassis ground - - -
(R423) No. 18 (T-SEN GND)↔ Chassis ground Resistance Always Less than 1 Ω
(R423) No. 19 (SEN-GND)↔ Chassis ground Resistance Always Less than 1 Ω
(R423) No. 20 (SEN-B)↔ Chassis ground Voltage When PRG is stopped 4 - 6 V