Execution Condition
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage Sub feedback Amount of intake air Estimated temperature of the rear oxygen sensor element Enable conditions at interrupt control are as follows Air fuel ratio reduced from target air fuel ratio Continuous time when rear oxygen sensor output voltage is less than 0.55 V |
10.9 V or more In operation 10 g/s (0.35 oz/s) or more 450°C (932°F) or more Equal to Value of Map 5000 ms or more |
VOLTAGE DESCRIPTION - MAP
| Rear oxygen sensor output voltage (V) | 0 | 0.1 | 0.15 | 0.3 | 0.4 | 0.5 | 0.6 |
|---|---|---|---|---|---|---|---|
| Air fuel ratio reduced from target air fuel ratio (%) | 15 | 15 | 5 | 4 | 4 | 4 | 4 |