LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Subaru >> 2019 >> BRZ Limited, Automatic Trans >> Repair and Diagnosis >> Body & Frame >> Windows >> Glass & Power Window System >> Power Window System >> Door Glass Does Not Fully Close In AUTO UP Operation (Auto-Reverse Function Is Activated) >> Inspection steps
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Inspection steps

  1. Power window system (initialization)
    1. Initialize the power window regulator motor ASSY LH (driver's seat) and power window regulator motor ASSY RH (passenger's seat), and verify normal operation. (Refer to REGISTRATION SETTINGS )

      Criteria: It operates properly.

      OK: Go to next step

      NG: Go to Step  2.

      Complete (due to failed initialization)

  2. Installation of door glass slide resistance (driver's door glass)
    1. Remove the door glass mounting bolts, and check if the door glass can be lifted with hands smoothly without being caught.
      NOTE:
      • The door glass is not in abnormal contact with the glass run.
      • Glass run has no deformation or foreign matter inside.

      OK: Go to next step

      NG: Install the glass properly (remove foreign matter which causes installation failure, fix the installation, or reinstall)

      Replacement of the power window regulator motor ASSY (driver's or passenger's seat) (Refer to REMOVAL )