Speed Sensor: Installation
- Installation of transmission revolution sensor (SP2)
- Apply auto fluid WS to a new O-ring and install it to the transmission revolution sensor (SP2).
- Install the transmission revolution sensor (SP2) with the bolt.
Standard value: T=5.4 N.m {55 kgf.cm} {4.0 ft-lbf}
- Connect the connector.
- Install the automatic transmission ASSY. (Refer to INSTALLATION )
- Installation of transmission revolution sensor (NT)
- Apply auto fluid WS to a new O-ring and install it to the transmission revolution sensor (NT).
- Install the transmission revolution sensor (NT) with the bolt.
Standard value: T=5.4 N.m {55 kgf.cm} {4.0 ft-lbf}
- Connect the connector.
- Installation of under cover COMPL T/M (refer to INSTALLATION )
- Installation of under cover front AL (refer to INSTALLATION )
- Data monitor check
(Refer to DATA MONITOR/ACTIVE TEST )