DTC P2017: TGV Position Sensor/Switch Circuit High Bank 1: Notes
DTC detecting condition:
Immediately at fault recognition
Trouble symptom:
- Improper idling
- Engine stalls.
- Poor driving performance
Wiring diagram:
Engine Electrical System Ref. to WIRING SYSTEM>ENGINE ELECTRICAL SYSTEM .
- CHECK DATA MONITOR.
- Start the engine.
- Using the Subaru Select Monitor, read the value in [TGV Position Sensor R].NOTE: For detailed operation procedures, refer to "Common (Diagnostics)". Ref. to COMMON (DIAG)>DATA MONITOR .
Is the value of [TGV Position Sensor R] 5 V or more?
Yes : Go to 2.
No : Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause. - CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR RH CONNECTOR (SHORT TO POWER SUPPLY).
- Turn the ignition switch to OFF.
- Disconnect the connector from tumble generator valve actuator RH.
- Start the engine.
- Using the Subaru Select Monitor, read the value in [TGV Position Sensor R].NOTE: For detailed operation procedures, refer to "Common (Diagnostics)". Ref. to COMMON (DIAG)>DATA MONITOR .
Is the value of [TGV Position Sensor R] 5 V or more?
Yes : Repair the short circuit to power in harness between ECM connector and tumble generator valve actuator RH connector.
No : Go to 3.
- CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR RH CONNECTOR (OPEN).
- Turn the ignition switch to OFF.
- Measure the resistance of harness between tumble generator valve actuator RH connector and engine ground.
Connector and terminal.
(E55) No. 2 - Engine ground:
Is the resistance less than 5 Ω?
Yes : Go to 4.
No : Repair the following item.
- Open circuit in harness between ECM connector and tumble generator valve actuator RH connector
- Poor contact of ECM connector
- Poor contact of J/C
- CHECK FOR POOR CONTACT.
Check for poor contact of tumble generator valve actuator RH connector.
Is there poor contact of the tumble generator valve actuator RH connector?
Yes : Repair the poor contact of tumble generator valve actuator RH connector.
No : Replace the tumble generator valve actuator RH. Ref. to FUEL INJECTION (FUEL SYSTEMS) (H4DOTC)>TUMBLE GENERATOR VALVE ACTUATOR .
NOTE: The tumble generator valve actuator cannot be disassembled.