Check Ignition Switch Circuit
- CHECK DATA MONITOR.
Display the data of [BATT voltage (control)] and [Power Supply Voltage] using Subaru Select Monitor. Refer to BODY CONTROL (DIAGNOSTICS)>DATA MONITOR .
Does the [Power Supply Voltage] indicate 0 V when the ignition switch is OFF, and fall within a range of ±1 V from the [BATT voltage (control)] when the ignition switch is ON?
Yes
The ignition switch input circuit is OK.
No
Go to 2.
- CHECK IGNITION SWITCH CIRCUIT.
- Turn the ignition switch to OFF.
- Disconnect the connector of body integrated unit.
- Turn the ignition switch to ON.
- Measure the voltage between the body integrated unit connector and chassis ground.
Connector & terminal
(i137) No. 12 (+) - Chassis ground (-):
Is the voltage 10 V or more?
Yes
Check body integrated unit. Refer to BODY CONTROL (DIAGNOSTICS)>BASIC DIAGNOSTIC PROCEDURE .
No
Check the harness for open or short circuit between body integrated unit and fuse.