Execution Condition
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | 10.9 V or more |
| Main feedback | In operation |
| Rear oxygen sensor voltage when fuel cut ends | Less than 0.15V |
| (Elapsed time of fuel cut Fuel shut-off function thereafter) | More than 5000ms Not in operation |
| Estimated temperature of rear oxygen sensor element when fuel cut ends | 500°C (932°F) or more |
| Compensation to rich | Rich |
| Amount of intake air | 20g/s (0.71oz/s) or more |