Remote Control Mirror Switch: Inspection
- Check the resistance between switch door mirror terminals.
Preparation tool:
Circuit tester
- Changeover switch, right side (model without electric retractable mirror)
Terminal No. Inspection conditions Standard 12- 1
12.- 18OFF 1 MΩ or more 12- 18
17- 1UP Less than 1 Ω 12- 17
18- 1DOWN Less than 1 Ω 12.- 16
18- 1LEFT Less than 1 Ω 12- 18
16- 1RIGHT Less than 1 Ω - Changeover switch, left side (model without electric retractable mirror)
Terminal No. Inspection conditions Standard 12- 1
12- 21OFF 1 MΩ or more 12- 20
21- 1DOWN Less than 1 Ω 12- 21
20- 1UP Less than 1 Ω 12- 19
21- 1LEFT Less than 1 Ω 12- 21
19- 1RIGHT Less than 1 Ω - Changeover switch, right side (model with electric retractable mirror)
Terminal No. Inspection conditions Standard 12- 1
12- 21OFF 1 MΩ or more 12- 21
17- 1UP Less than 1 Ω 12- 17
21- 1DOWN Less than 1 Ω 12- 16
21- 1LEFT Less than 1 Ω 12- 21
16- 1RIGHT Less than 1 Ω - Changeover switch, left side (model with electric retractable mirror)
Terminal No. Inspection conditions Standard 12- 1
12- 21OFF 1 MΩ or more 12- 20
21- 1DOWN Less than 1 Ω 12- 21
20- 1UP Less than 1 Ω 12- 19
21- 1LEFT Less than 1 Ω 12- 21
19- 1RIGHT Less than 1 Ω - Folding switch (model with electric retractable mirror)
Terminal No. Inspection conditions Standard 12- 5
4. 1Retraction Less than 1 Ω 12- 4
5- 1Unfolding Less than 1 Ω - If the inspection result is not within the standard value, replace the switch assembly power window main.