Combination Meter System: Inspection: Switch
Illumination intensity does not change even when the illumination control switch is operated.
- CHECK CURRENT DATA
.
Display the data of [Bright switch input state] and [Illumination control switch input state] using Subaru Select Monitor. Ref. to COMBINATION METER (DIAGNOSTICS)>DATA MONITOR .
Do the display change as [OFF] ←→ [ON] and the value range from 0 to 100 when the bright switch and illumination control switch are operated?
Yes : Replace the combination meter assembly.
No : Go to 2.
- CHECK ILLUMINATION CONTROL SWITCH UNIT
.
Check the illumination control switch. INSTRUMENTATION/DRIVER INFO>Switches and Harness>INSPECTION>ILLUMINATION CONTROL SWITCH .
Is the switch normal?
Yes : Go to 3.
No : Replace the illumination control switch.
- CHECK HARNESS
.
- Disconnect the connectors of combination meter assembly and illumination control switch.
- Measure the resistance between the combination meter assembly and the illumination control switch.
Connector & terminal
(i10) No. 29 - (i79) No. 6:
(i10) No. 30 - (i79) No. 5:
(i10) No. 31 - (i79) No. 4:
(i10) No. 32 - (i79) No. 1:
Is the resistance less than 1 Ω?
Yes : Replace the combination meter assembly.
No : Repair or replace the harness.