Operation Procedure B
NOTE:
With [Write ECU setting 12 columns of models], carry-over of odometer value cannot be performed.
- Replace the combination meter assembly with a new part. Ref. to INSTRUMENTATION/DRIVER INFO>Combination Meter .
- Write the vehicle data.
- Connect the Subaru Select Monitor and then turn the ignition switch to ON.
- On [Start] screen, select [Diagnosis].
- On [Vehicle selection] screen, enter vehicle information and select [OK].
- On [Main Menu] screen, select [Each System].
- On [Select System] screen, select [Combination Meter], and then select [Next].
- On [Select Function] screen, select [Work Support], and then select [Reading and Writing of the ECU Configuration Information and Odometer Value].
- From the item list, select [Write ECU setting 12 columns of models]. Enter the applied model and click the [OK] button. Ref. to IDENTIFICATION>IDENTIFICATION NUMBER & LABEL LOCATIONS .
- Enter the option code (4 digits) and click the [OK] button. Ref. to IDENTIFICATION NUMBER & LABEL LOCATIONS .
- Confirm the vehicle information on [Write ECU setting 12 columns of models] screen, and click the [OK] button.
- When [Write?] is displayed, select the [Yes] button.
- Confirm that [Write operation is complete.] is displayed, and click the [OK] button.
- Check if the combination meter assembly operates normally.