Memory Height SW Does Not Function
- CHECK CENTER INFORMATION DISPLAY
.
Operate the memory height SW and check if the display for the memory height SW changes.
Does the display change?
Yes: The circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.No: Go to 2 .
- CHECK DATA MONITOR
.
Using the Subaru Select Monitor, check the following items in the [Data Monitor] of [Power Rear Gate]. Ref. to Power Rear Gate (Diagnostics)>Data Monitor .
- Memory stop SW
Does the display switch between [OFF] ←→ [ON] according to memory height SW operation?
Yes: Input circuit is normal. Perform the inspection according to the diagnosis for cockpit control system. Ref. to COCKPIT CONTROL (DIAGNOSTICS)>BASIC DIAGNOSTIC PROCEDURE>PROCEDURE .
No: Replace Power rear gate control module. Ref. to POWER REAR GATE SYSTEM>POWER REAR GATE CONTROL MODULE .