VDC OFF Switch: Inspection
- Measure the resistance between the VDC OFF switch terminals.
Terminal No. Inspection conditions Standard 6 - 8 Switch OFF 1 MΩ or more Switch ON Less than 1 Ω - Apply battery voltage between the connector terminals to check lighting condition of illumination inside the switch.CAUTION:
When applying battery voltage, do not mix up the positive (+) side and the negative (-) side.
Incorrect polarity connection may cause LED damage inside the switch.
Terminals No. Inspection conditions Specification 1 (+) - 4 (-) Apply battery voltage. Light ON - Replace the VDC OFF switch if it is found defective.