Check Trunk Opener Switch Circuit
Wiring diagram:
Door lock control system Ref. to WIRING SYSTEM>DOOR LOCK CONTROL SYSTEM>WIRING DIAGRAM .
- CHECK DATA MONITOR
.
Display the [R Gate Release SW input] data using Subaru Select Monitor. Ref. to BODY CONTROL (DIAGNOSTICS)>DATA MONITOR>OPERATION .
Does the display switch between [OFF] ←→ [ON] when the trunk opener switch is operated?
Yes: The trunk opener switch is normal.
No: Go to 2.
- CHECK HARNESS
.
- Disconnect the connectors of body integrated unit and trunk opener switch.
- Check the harness between body integrated unit and trunk opener switch.
Connector & terminal
(i82) No. 6 - (i140) No. 1:
Is harness normal?
Yes: Go to 3.
No: Repair or replace the harness.
- CHECK HARNESS
.
Measure the resistance between trunk opener switch connector and chassis ground.
Connector & terminal
(i140) No. 4 - Chassis ground:
Is the resistance less than 10 Ω?
Yes: Go to 4.
No: Repair or replace the harness.
- CHECK TRUNK OPENER SWITCH
.
Measure the resistance between terminals both when trunk opener switch is pressed and when not pressed.
Terminals
No. 1 - No. 4:
Is the resistance less than 10 Ω when the switch is pressed and 1 MΩ or more when not pressed?
Yes: Replace the body integrated unit. Ref. to BODY CONTROL/COMMUNICATION SYSTEM>BODY INTEGRATED UNIT .
No: Replace the trunk opener switch. Ref. to SECURITY AND LOCKS>TRUNK OPENER SWITCH .