Switch Power Window Sub Front
- Measure the resistance between terminals of the switch power window sub front.
Terminal No. Inspection conditions Standard 6 - 5 OFF Less than 1 Ω 2 - 1
2 - 5
2 - 61 MΩ or more 2 - 6 Manual up Less than 1 Ω 5 - 6
2 - 5
1 - 21 MΩ or more 2 - 6
1 - 2Auto up Less than 1 Ω 5 - 6
2 - 51 MΩ or more 2 - 5 Manual down Less than 1 Ω 5 - 6
2 - 6
1 - 21 MΩ or more 2 - 5
1 - 2Auto down Less than 1 Ω 5 - 6
2 - 61 MΩ or more - Apply battery voltage between the switch power window sub front terminals to check lighting condition of illumination inside the switch.CAUTION: When applying battery voltage, do not mix up the positive (+) side and the negative (-) side.CAUTION: Incorrect polarity connection may cause LED damage inside the switch.
Terminal No. Inspection conditions Specification 7 (+) - 2 (-) Apply battery voltage Light ON - Replace the switch power window sub front if it is found defective from the inspection result.