Operation Procedure A
CAUTION:
- Carry-over of the odometer value is possible only once. If failed, odometer carry-over cannot be performed anymore.
- When odometer value reading is performed, the odometer displays "_______" and continued use of the combination meter assembly is impossible.
- When the power supply of the Subaru Select Monitor is turned OFF during work, the odometer value data is cleared and carry-over becomes impossible. Be careful of the state of power supply connection of Subaru Select Monitor.
- Read and store the setting information and odometer value.
- Connect the Subaru Select Monitor and then turn the ignition switch to ON.
- Select [Reading and Writing of the ECU Configuration Information and Odometer Value] on [Work Support] of Subaru Select Monitor. Ref. to COMMON (DIAGNOSTICS)>WORK SUPPORT>OPERATION .
- Save under a new name according to the display screen.
- When [Do you read the Odometer Value? Odometer of the Meter is locked] is displayed, select the [YES] button.
- Confirm that [Read the Odometer Value] is displayed, and then turn the ignition switch to OFF.
- Replace the combination meter assembly with a new part. Ref. to INSTRUMENTATION/DRIVER INFO>COMBINATION METER .CAUTION: Do not perform the following. Otherwise, saved odometer values will be cleared.
- Turn the power supply of Subaru Select Monitor to OFF.
- Communication between Subaru Select Monitor and interface for Subaru Select Monitor is lost. (USB cable is disconnected)
NOTE: The data link connector can be removed. If it is interfering with the work, move it outside the vehicle. - Write the setting information and odometer value.NOTE: When the odometer value writing operation is completed correctly, the odometer value is automatically cleared from the Subaru Select Monitor.
- [Did you replace the Meter?] is displayed. Select the [YES] button.
- When [Do you write Odometer Value?] is displayed, select the [YES] button.
- When [Completed the writing of Odometer Value. Write the ECU Configuration Information] is displayed, select the [OK] button.
- Select the file saved with [Reading and Writing of the ECU Configuration Information and Odometer Value], and click the [Execution] button.
- When [Write?] is displayed, select the [YES] button.
- Confirm that [Write operation was completed.] is displayed, and click the [OK] button.
- Check if the combination meter assembly operates normally.