Operation Procedure B
NOTE:
With [Write ECU setting 12 columns of models], carry-over of odometer value cannot be performed.
- Replace the combination meter assembly with a new part. Ref. to INSTRUMENTATION/DRIVER INFO>COMBINATION METER .
- Write the vehicle data.
- Connect the Subaru Select Monitor and then turn the ignition switch to ON.
- Select [Write Control module setting information] on [Work Support] of Subaru Select Monitor. Ref. to COMMON (DIAGNOSTICS)>WORK SUPPORT .
- From the item list, select [Write ECU setting 12 columns of models]. Enter the applied model (7 digits) and click the [OK] button. Ref. to IDENTIFICATION>IDENTIFICATION NUMBER & LABEL LOCATIONS .
- Enter the option code (4 digits) and click the [OK] button. Ref. to IDENTIFICATION>IDENTIFICATION NUMBER & LABEL LOCATIONS .
- Confirm the vehicle information on [Write ECU setting 12 columns of models] screen, and click the [OK] button.
- When [Write?] is displayed, select the [YES] button.
- Confirm that [Write operation is complete.] is displayed, and click the [OK] button.
- Check if the combination meter assembly operates normally.