Power Steering Pressure Switch
ECM applies and monitors reference voltage to power steering pressure switch from ECM terminal A6 on TBI or ECM terminal A19 on MFI.
When steering wheel is turned, pressure switch closes, pulling reference voltage low. ECM uses this signal to help determine control of idle speed control system.