Secondary Parameters And Enable Conditions
Electrical Error:
Ignition ON
Configuration byte for DIAGCP > 1
Battery voltage condition fulfilled for OBD-II diagnosis = true
Constant signal:
Engine stopped = false
Battery voltage condition fulfilled for OBD-II diagnosis = true
DTP stuck sensor diagnosis inhibition = false
Configuration byte for DIAGCP > 1
Minimum TAM for activation of DIAGCP
> -3.75 °C
Minimum purge flow fluctuation for diagnosis > 0.05 kg/h
Pressure sensor Voltage for Diagnosis > 0.298 V
Minimum vehicle speed for diagnosis > 45 km/h
=> DTP constant signal diagnosis = ON
Noisy Error:
Battery voltage condition fulfilled for OBD-II diagnosis = true
DTP noisy sensor diagnosis inhibition = false
DTP noisy signal diagnosis = active