Transmission Fluid Temperature Sensor Specifications
TRANSMISSION FLUID TEMPERATURE SENSOR SPECIFICATIONS
| Temperature | Temperature | Minimum Resistance | Nominal Resistance | Maximum Resistance |
|---|---|---|---|---|
| °C | °F | Ω | Ω | Ω |
| -40 °C | -40 °F | 59500 | 77480 | 100000 |
| -30 °C | -22 °F | 39688 | 44000 | 48400 |
| -20 °C | -4 °F | 21731 | 25880 | 29006 |
| -10 °C | 14 °F | 13156 | 15730 | 17587 |
| 0 °C | 32 °F | 8299 | 9846 | 11735 |
| 10 °C | 50 °F | 5952 | 6445 | 6912 |
| 20 °C | 68 °F | 3802 | 4184 | 4601 |
| 30 °C | 86 °F | 2582 | 2829 | 3167 |
| 40 °C | 104 °F | 1742 | 1955 | 2189 |
| 50 °C | 122 °F | 1257 | 1379 | 1514 |
| 60 °C | 140 °F | 893 | 992 | 1097 |
| 70 °C | 158 °F | 621 | 726 | 789 |
| 80 °C | 176 °F | 510 | 541 | 596 |
| 90 °C | 194 °F | 371 | 409 | 442 |
| 100 °C | 212 °F | 299 | 314 | 336 |
| 110 °C | 230 °F | 226 | 247 | 262 |
| 120 °C | 248 °F | 180 | 192 | 201 |
| 130 °C | 266 °F | 143 | 153 | 161 |
| 140 °C | 284 °F | 114 | 124 | 134 |
| 150 °C | 302 °F | 97 | 101 | 105 |