Monitoring Procedure
Input signal of the following are checked for open, short of circuit by monitoring input voltage.
- Primary and secondary pressure sensor power supply circuit (P0641)
- Transmission range sensor (P0707)
- CVT fluid temperature sensor (P0712, P0713)
- Primary pulley pressure sensor (P0842, P0843)
- Secondary pressure sensor (P0847, P0848)
- Line pressure control solenoid valve (P0962, P0963)
- Secondary pressure control solenoid valve (P0966, P0967)
- Sensor ground circuit (P1970)
- TCC solenoid valve (P2763, P2764)