CMP Control System Monitor
CMP CONTROL SYSTEM MONITOR OPERATION
| DTCs |
P0010 |
| Monitor execution |
Not applicable |
| Monitoring duration |
2, 000 msec. |
| DTCs |
P0011, P0012 |
| Monitor execution |
Not applicable |
| Monitoring duration |
4 sec. |
| DTCs |
P0016 |
| Monitor execution |
Not applicable |
| Monitoring duration |
1, 024 msec. |
ENABLE CONDITIONS
| Parameter |
Min. |
Max. |
| P0010 |
| Phase 1 |
| OCV duty |
45% |
- |
| Phase 2 |
| OCV duty |
- |
15% |
| P0011, P0012 |
| Time after VVT control start |
16 sec. |
- |
| OCV |
No DTC (P0010) |
| CKP sensor |
No DTC (P0335) |
| CMP sensor |
No DTC (P0340) |
| P0016 |
| Target CMP control system |
= 0 ° |
TYPICAL MALFUNCTION THRESHOLDS
| P0010 |
| Phase 1: |
OCV current < 0.2 A |
| Phase 2: |
OCV current > 0.8 A |
| P0011: CMP control system target - actual < -12 ° |
| P0012: CMP control system target - actual > 15 ° |
| P0016 |
| Phase 1: |
CKP - CMP difference at the end of last driving cycle > CKP - CMP difference +10 ° |
| Phase 2: |
CKP - CMP difference at the end of last driving cycle < CKP - CMP difference - 10 ° |
| Phase 3: |
CKP - CMP difference < 3 ° |
| Phase 4: |
CKP - CMP difference > 29 ° |
MODE $06 DATA
| MID |
Test item (related DTC) |
TID |
Description |
Scaling |
UNIT |
UASID |
| $35 |
VVT Monitor Bank 1 (P0011) |
$DA |
Differential angle |
(Signed) N*0.01 |
deg |
$9C |
| $35 |
VVT Monitor Bank 1 (P0012) |
$DB |
Differential angle |
(Signed) N*0.01 |
deg |
$9C |