Flow Control Valve and Its Spring
- Check fluid passage of flow control valve and orifice of connector for obstruction (clogged).
- Check sliding surface of flow control valve for wear and damage.
- Check free length of flow control valve spring (1).
Free length of flow control valve spring
Standard: 22.0 mm (0.866 in.)
Limit: 21.0 mm (0.827 in.)
- Replace if any defective is found.