LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Toyota >> 1988 >> Van Base, Van Window >> Repair and Diagnosis >> Engine Performance >> Testing & Diagnosis >> Computer Control System >> Component Testing >> Airflow Meter
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Airflow Meter

Turn ignition off. Disconnect wiring connector from airflow meter. Note terminal identification. See Fig 1 Using an ohmmeter, measure resistance between specified terminals. Replace airflow meter if not within specification. See AIRFLOW METER RESISTANCE SPECIFICATIONS  table.

Fig 1: Airflow Meter Terminal Identification
G95390Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
AIRFLOW METER RESISTANCE SPECIFICATIONS

Application Terminals Ohms
E2-THA
-4°F (20°C) 10,000-20,000
32°F (0°C) 4000-7000
68°F (20°C) 2000-3000
104°F (40°C) 900-1300
140°F (60°C) 400-700
E2-Vc 100-300
E2-Vb 200-400
E1-Fc
Measuring Plate Fully Closed Infinity
Measuring Plate Other Than Closed 0
E2-Vs
Fully Closed 20-400
Fully Open 20-1000