Sensor Operating Specifications

NOTE: Perform all voltage tests with a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance, unless stated otherwise in test procedure.
AIRFLOW METER RESISTANCE SPECIFICATIONS

Application & Terminals Ohms
2.0L Engine
E2-Vc 3000-7000
E1-Fc
Measuring Plate Fully Closed No Continuity
Measuring Plate Other Than Closed 0
E2-Vs
Measuring Plate Fully Closed 200-600
Measuring Plate Fully Opened 20-1000
2.5L Engine
E2-Vc 200-400
E1-Fc
Measuring Plate Fully Closed No Continuity
Measuring Plate Other Than Closed 0
E2-Vs
Measuring Plate Fully Closed 200-600
Measuring Plate Fully Opened 20-1000
All Engines
E2-THA
-4°F (-20°C) 10,000-20,000
32°F (0°C) 4000-7000
68°F (20°C) 2000-3000
104°F (40°C) 900-1300
140°F (60°C) 400-700
COLD START INJECTOR RESISTANCE SPECIFICATIONS

Application (1) Ohms
Camry 2.0-4.0
(1) Measure resistance between injector terminals.
COLD START INJECTOR TIME SWITCH RESISTANCE SPECIFICATIONS

Terminals Temperature: °F (°C) Ohms
STA-STJ Less Than 59 (15) 25-45
" Greater Than 86 (30) 65-85
STA-Ground N/A 25-85
NOTE: For coolant temperature sensor specifications see Fig 1.
Fig 1: Coolant Temperature Sensor Specifications
G119427Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
EGR GAS TEMP SENSOR SPECIFICATIONS

Temperature: °F (°C) (1) Ohms
122 (50) 69-89
212 (100) 12-14
302 (150) 3-4
(1) Measure resistance between sensor terminals.
FUEL INJECTOR RESISTOR SPECIFICATIONS

Application (1) Ohms
Camry Approx. 13.8
(1) Measured across terminals at 68°F (20°C).
ISC VALVE RESISTANCE SPECIFICATIONS

Application Ohms
3S-FE (1) 16-17
2VZ-FE (2) 10-30
(1) Measure resistance between terminals +B and ISC1, and between ISC2 and +B of ISC valve connector.
(2) Measure resistance between terminals B1 to S1 or S3 and terminals B2 to S2 or S.
OXYGEN SENSOR HEATER RESISTANCE SPECIFICATIONS

Condition Ohms
68°F (20°C) (1) 5.1-6.3
(1) Measure between terminals B+ and HT.
TPS RESISTANCE SPECIFICATIONS

Model/ Application Clearance In. (mm) Terminal Identification Ohmmeter Reading
2.0L (W/O ECT) .020 (.51) IDL & E1 Continuity
" " PSW & E1 No Continuity
" .035 (.90) IDL & E1 No Continuity
" " PSW & E1 No Continuity
" Fully Open IDL & E1 No Continuity
" " PSW & E1 Continuity
2.0L (W/ ECT) 0 (0) VTA & E2 200-800
" .020 (.51) IDL & E2 2300 or Less
" .028 (.70) IDL & E2 No Continuity
" Fully Open VAT & E2 3300-10,000
" " VC & E2 3000-7000
2.5L 0 (0) VTA & E2 300-6300
" .012 (.30) IDL & E2 2300 or Less
" .028 (.71) IDL & E2 No Continuity
" Fully Open VTA & E2 3500-10,300
" " VC & E2 4250-8250