Vacuum Switch Test
Locate vacuum switch and disconnect switch connector. See Figure. Connect a vacuum pump to switch. See Fig 1. With no vacuum applied, continuity should exist between switch terminals. With vacuum applied, no continuity should exist between switch terminals. If continuity is not as specified, replace vacuum switch.