Throttle Position (TP) Sensor
MAIN TP SENSOR RESISTANCE SPECIFICATIONS
| Application Type |
Clearance In. (mm) |
Terminals Tested |
Ohmmeter Reading |
| Supra |
Fully Closed |
VTA & E2 |
340-6300 |
| " |
.021 (.54) |
IDL & E2 |
500 Or Less |
| " |
.028 (.70) |
IDL & E2 |
No Continuity |
| " |
Fully Open |
VTA & E2 |
2400-11,200 |
| " |
" |
VC & E2 |
3100-7200 |
SUB-TP SENSOR RESISTANCE SPECIFICATIONS
| Application Type |
Clearance In. (mm) |
Terminals Tested |
Ohmmeter Reading |
| Supra |
Fully Closed |
VTA & E2 |
300-6300 |
| " |
.016 (.40) |
IDL & E2 |
500 Or Less |
| " |
.019 (.48) |
IDL & E2 |
No Continuity |
| " |
Fully Open |
VTA & E2 |
200-10,800 |
| " |
" |
VC & E2 |
3500-6500 |