Inspection Procedure
- Check pattern select switch (2nd start switch).
PREPARATION:
Disconnect the pattern select switch connector.
CHECK:
Check continuity between terminals 2 and 3 of pattern select switch connector when pattern select switch is set to 2nd start switch ON and OFF.
OK:
2ND START SWITCH AND SPECIFIED CONDITION2nd start switch Specified condition Press continuously "2nd" switch Continuity Release "2nd" switch No continuity Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- NG: Replace the pattern select switch.
- OK: Go to next step.
- Check harness and connector between terminal SNWI of ECM and body ground.
PREPARATION:
- Connect the pattern select switch connector.
- Disconnect the connector of ECM.
CHECK:
Check continuity between terminal SNWI of ECM and body ground when the pattern select switch is set to 2nd start switch ON and OFF.
OK:
2ND START SWITCH AND SPECIFIED CONDITION2nd start switch Specified condition Press continuously "2nd" switch Continuity Release "2nd" switch No Continuity - OK: Proceed to next circuit inspection shown on matrix table (See PROBLEM SYMPTOMS TABLE ).
- NG: Repair or replace harness or connector (See HOW TO USE THE DIAGNOSTIC TABLE AND INSPECTION ).