Inspection Procedure
- CHECK MULTIPLEX COMMUNICATION SYSTEM
- Check that the multiplex communication system operates normally.
OK: Multiplex communication system operates normally.
- NG: Go to MULTIPLEX COMMUNICATION SYSTEM (See HOW TO PROCEED WITH TROUBLESHOOTING )
- OK: GO TO NEXT STEP
- Check that the multiplex communication system operates normally.
- CHECK OPERATION OF COMBINATION METER
- After replacing the combination meter with a new one, check that the smart indicator operates normally.
OK: Smart indicator operates normally.
- NG: REPLACE SMART KEY ECU ASSY
- OK: GO TO NEXT STEP
END