Inspection Procedure
- CHECK ECM (+B VOLTAGE)
- Turn the ignition switch ON.
- Measure the voltage of the ECM connectors.
Standard voltage
TERMINALS VOLTAGE SPECIFICATIONTester Connection Specified Condition +B (E8-1) - E1 (E6-1) 9 to 14V
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
NG: GO TO NEXT STEP
- CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
- Disconnect the E6 ECM connector.
- Measure the resistance of the wire harness side connector.
Standard resistance
TERMINALS RESISTANCE SPECIFICATIONTester Connection Specified Condition E1 (E6-1) - Body ground Below 1 Ω
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: GO TO NEXT STEP
- CHECK ECM (IGSW VOLTAGE)
- Turn the ignition switch ON.
- Measure the voltage of the ECM connectors.
Standard voltage
TERMINALS VOLTAGE SPECIFICATIONTester Connection Specified Condition IGSW (E8-9) - E1 (E6-1) 9 to 14 V
OK: Go to step 6
NG: GO TO NEXT STEP
- INSPECT FUSE (IGN)
- Remove the IGN fuse from the instrument panel junction block RH.
- Measure the resistance of the IGN fuse.
Standard resistance:
Below 1 Ω
NG: REPLACE FUSE
OK: GO TO NEXT STEP
- INSPECT IGNITION SWITCH ASSEMBLY
- Remove the lower finish panel.
- Disconnect the I18 ignition switch connector.
- Measure the resistance of the ignition switch.
Standard resistance
TERMINALS RESISTANCE SPECIFICATIONSwitch position Tester Connection Specified Condition LOCK All Terminals 10 kΩ or higher ACC 2-3 Below 1 Ω ON 2-3, 2-4 6-7 START 1-2, 2-4 6-7, 6-8 - Reconnect the ignition switch connector.
NG: REPLACE IGNITION SWITCH ASSEMBLY
OK: REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY - IGNITION SWITCH, IGNITION SWITCH-ECM)
- CHECK ECM (MREL VOLTAGE)
- Turn the ignition switch ON.
- Measure the voltage of the ECM connectors.
Standard voltage
TERMINALS VOLTAGE SPECIFICATIONTester Connection Specified Condition MREL (E8-8) - E1 (E6-1) 9 to 14 V
NG: REPLACE ECM
OK: GO TO NEXT STEP
- INSPECT FUSE (EFI)
- Remove the EFI fuse from the engine room junction block.
- Measure the resistance of the EFI fuse.
Standard resistance:
Below 1 Ω
NG: REPLACE FUSE
OK: GO TO NEXT STEP
- INSPECT EFI RELAY (Marking: EFI)
- Remove the EFI relay from the engine room junction block.
- Measure the resistance of the EFI relay.
Standard resistance
TERMINALS RESISTANCE SPECIFICATIONTerminal Connection Specified Condition 3-5 10 kΩ or higher 3-5 Below 1 Ω (when battery voltage Is applied to terminals 1 and 2) - Reinstall EFI relay.
NG: REPLACE EFI RELAY
OK: GO TO NEXT STEP
- CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
- Disconnect the E8 ECM connector.
- Measure the resistance between the wire harness side connector and body ground.
Standard resistance
TERMINALS RESISTANCE SPECIFICATIONTester Connection Specified Condition MREL (E8-8) - Body ground Below 1 Ω - Reconnect the ECM connector.
OK: REPAIR OR REPLACE HARNESS OR CONNECTOR
NG: CHECK FOR INTERMITTENT PROBLEMS