Charging System: Generator: Inspection
- INSPECT GENERATOR WITH CLUTCH PULLEY
- When rotating the generator pulley, check that it turns counterclockwise and does not turn clockwise.
- INSPECT GENERATOR BRUSH HOLDER ASSEMBLY
- Using vernier calipers, measure the exposed brush length.
Standard exposed length:
10.5 mm (0.413 in.)
Minimum exposed length:
4.5 mm (0.177 in.)
If the exposed length is less than the minimum, replace the generator brush holder assembly.
- Using vernier calipers, measure the exposed brush length.
- INSPECT GENERATOR ROTOR ASSEMBLY
- Check that the generator rotor bearing is not rough or worn.
If necessary, replace the generator rotor.
- Check the generator rotor for an open circuit.
- Using an ohmmeter, measure the resistance between the slip rings.
Standard resistance:
2.3 to 2.7 Ω at 20°C (68°F)
If the result is not as specified, replace the generator rotor assembly.
- Using an ohmmeter, measure the resistance between the slip rings.
- Check the generator rotor for a short circuit.
- Using an ohmmeter, measure the resistance between the each slip ring and rotor.
Standard resistance:
1 MΩ or higher
If the result is not as specified, replace the generator rotor assembly.
- Using an ohmmeter, measure the resistance between the each slip ring and rotor.
- Using vernier calipers, measure the slip ring diameter.
Standard diameter:
14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum diameter:
14.0 mm (0.551 in.)
If the diameter is less than the minimum, replace the generator rotor assembly.
- Check that the generator rotor bearing is not rough or worn.
- INSPECT GENERATOR DRIVE END FRAME BEARING
- Check the generator drive end frame bearing is not rough or worn.
If necessary, replace the generator drive end frame bearing.
- Check the generator drive end frame bearing is not rough or worn.