Inspection Procedure
- CHECK FUSE (ECU-B)
- Remove the fuse from the instrument panel J/B.
- Measure the resistance of the fuse.
Standard resistance:
Below 1 Ω
NG: REPLACE FUSE
OK : Go to Next Step
- CHECK TVIP ECU
- Disconnect the TVIP ECU connector.
- Measure the voltage according to the value(s) in the table below.
Standard voltage
VOLTAGE SPECIFICATIONTester Connection Specified Condition +B1 (T3-2) - Body ground 10 to 14 V
NG: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
OK : Go to Next Step
- CHECK HARNESS AND CONNECTOR (TVIP ECU - BODY GROUND)
- Disconnect the TVIP ECU connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Specified Condition E (T3-29) - Body ground Below 1 Ω
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK : REPLACE TVIP ECU