Measure the resistance according to the value(s) in the table below.Standard Resistance
RESISTANCE REFERENCE
| Tester Connection |
Condition |
Specified Condition |
| 1 - 2 |
20°C (68°F) |
560 to 680 Ω |
If the resistance value is not as specified, replace the speed sensor.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002