Mass Air Flow Meter: Inspection: Inspection
- INSPECT MASS AIR FLOW METER
- Perform a visual check for any foreign matter on the platinum hot wire (heater) of the mass air flow meter shown in the illustration.
OK
There is no foreign matter.
If the result is not as specified, replace the mass air flow meter.
TEXT IN ILLUSTRATION*1 Platinum Hot Wire (Heater) - Check the resistance.TEXT IN ILLUSTRATION
*a Component without harness connected
(MAF Meter)*b Resistance *c Temperature *d Acceptable - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 4 (THA) - 5 (E2) -20 °C (-4 °F) 12.5 to 16.9 kΩ 20 °C (68 °F) 2.19 to 2.67 kΩ 60 °C (140 °F) 0.50 to 0.68 kΩ If the result is not as specified, replace the mass air flow meter.
- Measure the resistance according to the value(s) in the table below.
- Perform a visual check for any foreign matter on the platinum hot wire (heater) of the mass air flow meter shown in the illustration.