DTC P0607: Control Module Performance: Procedure
- CHECK ANY OTHER DTCS OUTPUT
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON and turn the Techstream on.
- Enter the following menu: Powertrain / Engine and ECT / Trouble Codes.
- Read the DTC.RESULT
Result Proceed to P0607 and P0136, P0137, P0138, P0156, P0157 or P0158 are output A P0607 is output B
B → See step 3
A: Go to next step
- INSPECT DTC (P0136, P0137, P0138, P0156, P0157 OR P0158)
- Inspect the P0136, P0137, P0138, P0156, P0157 or P0158 flow chart.
HINT:
- If P0136 or P0156 is output, troubleshoot for that DTC first. Refer to DTC P0136: Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2); DTC P0137: Oxygen Sensor Circuit Low Voltage (Bank 1 Sensor 2); DTC P0138: Oxygen Sensor Circuit High Voltage (Bank 1 Sensor 2); DTC P0139: Oxygen Sensor Circuit Slow Response (Bank 1 Sensor 2); DTC P0156: Oxygen Sensor Circuit Malfunction (Bank 2 Sensor 2); DTC P0157: Oxygen Sensor Circuit Low Voltage (Bank 2 Sensor 2); DTC P0158: Oxygen Sensor Circuit High Voltage (Bank 2 Sensor 2); DTC P0159: Oxygen Sensor Circuit Slow Response (Bank 2 Sensor 2) . Then proceed to 6 "INSPECT ECM".
- If P0137 or P0157 is output, troubleshoot for that DTC first. Refer to DTC P0136: Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2); DTC P0137: Oxygen Sensor Circuit Low Voltage (Bank 1 Sensor 2); DTC P0138: Oxygen Sensor Circuit High Voltage (Bank 1 Sensor 2); DTC P0139: Oxygen Sensor Circuit Slow Response (Bank 1 Sensor 2); DTC P0156: Oxygen Sensor Circuit Malfunction (Bank 2 Sensor 2); DTC P0157: Oxygen Sensor Circuit Low Voltage (Bank 2 Sensor 2); DTC P0158: Oxygen Sensor Circuit High Voltage (Bank 2 Sensor 2); DTC P0159: Oxygen Sensor Circuit Slow Response (Bank 2 Sensor 2) . Then proceed to 6 INSPECT ECM.
- If P0138 or P0158 is output, troubleshoot for that DTC first. Refer to DTC P0136: Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2); DTC P0137: Oxygen Sensor Circuit Low Voltage (Bank 1 Sensor 2); DTC P0138: Oxygen Sensor Circuit High Voltage (Bank 1 Sensor 2); DTC P0139: Oxygen Sensor Circuit Slow Response (Bank 1 Sensor 2); DTC P0156: Oxygen Sensor Circuit Malfunction (Bank 2 Sensor 2); DTC P0157: Oxygen Sensor Circuit Low Voltage (Bank 2 Sensor 2); DTC P0158: Oxygen Sensor Circuit High Voltage (Bank 2 Sensor 2); DTC P0159: Oxygen Sensor Circuit Slow Response (Bank 2 Sensor 2) . Then proceed to 6 INSPECT ECM.
- If DTC P0607 and P0136, P0137, P0138, P0156, P0157 or P0158 are output, the output voltage of the heated oxygen sensor may remain close to 0 V or become high (around 1 V or more).
NEXT → See step 6
- Inspect the P0136, P0137, P0138, P0156, P0157 or P0158 flow chart.
- CHECK FOR EXHAUST GAS LEAK
- Allow the engine to idle and rev the engine.
- Check for exhaust gas leaks around the heated oxygen sensor.
If any exhaust gas leaks are present, repair them and proceed to 4 "PERFORM CONFIRMATION DRIVING PATTERN". If no exhaust gas leaks are present proceed to 4 "PERFORM CONFIRMATION DRIVING PATTERN".
HINT:
- If no exhaust gas leaks are present, a malfunction in the heated oxygen sensor circuit is suspected.
- If any exhaust gas leaks are present around the heated oxygen sensor, noise appears in the output voltage of the heated oxygen sensor.
NEXT: Go to next step
- PERFORM CONFIRMATION DRIVING PATTERN
- Clear DTC. Refer to DTC CHECK / CLEAR .
- Connect the Techstream to the DLC3.
- Start the engine.
- Warm up the engine until the engine coolant temperature becomes 75°C (167°F) or more.
- Perform the drive pattern.WARNING:
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
- Accelerate the vehicle to 80 km/h (50 mph) and stop the vehicle.
- Drive the vehicle between 56 and 80 km/h (35 and 50 mph) for 5 minutes.
- Enter the following menu: Powertrain / Engine and ECT / Trouble Codes.
- Read the DTCs.RESULT
Result Proceed to P0607 and P0136, P0137, P0138, P0156, P0157 or P0158 are output A Only P0607 B No DTC output C
B → See step 7
C → See step 6
A: Go to next step
- INSPECT DTC (P0136, P0137, P0138, P0156, P0157 OR P0158)
- Inspect the P0136, P0137, P0138, P0156, P0157 or P0158 flow chart.
HINT:
- If P0136 or P0156 is output, troubleshoot for that DTC first. Refer to DTC P0136: Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2); DTC P0137: Oxygen Sensor Circuit Low Voltage (Bank 1 Sensor 2); DTC P0138: Oxygen Sensor Circuit High Voltage (Bank 1 Sensor 2); DTC P0139: Oxygen Sensor Circuit Slow Response (Bank 1 Sensor 2); DTC P0156: Oxygen Sensor Circuit Malfunction (Bank 2 Sensor 2); DTC P0157: Oxygen Sensor Circuit Low Voltage (Bank 2 Sensor 2); DTC P0158: Oxygen Sensor Circuit High Voltage (Bank 2 Sensor 2); DTC P0159: Oxygen Sensor Circuit Slow Response (Bank 2 Sensor 2) . Then proceed to 6 "INSPECT ECM".
- If P0137 or P0157 is output, troubleshoot for that DTC first. Refer to DTC P0136: Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2); DTC P0137: Oxygen Sensor Circuit Low Voltage (Bank 1 Sensor 2); DTC P0138: Oxygen Sensor Circuit High Voltage (Bank 1 Sensor 2); DTC P0139: Oxygen Sensor Circuit Slow Response (Bank 1 Sensor 2); DTC P0156: Oxygen Sensor Circuit Malfunction (Bank 2 Sensor 2); DTC P0157: Oxygen Sensor Circuit Low Voltage (Bank 2 Sensor 2); DTC P0158: Oxygen Sensor Circuit High Voltage (Bank 2 Sensor 2); DTC P0159: Oxygen Sensor Circuit Slow Response (Bank 2 Sensor 2) . Then proceed to 6 "INSPECT ECM".
- If P0138 or P0158 is output, troubleshoot for that DTC first. Refer to DTC P0136: Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2); DTC P0137: Oxygen Sensor Circuit Low Voltage (Bank 1 Sensor 2); DTC P0138: Oxygen Sensor Circuit High Voltage (Bank 1 Sensor 2); DTC P0139: Oxygen Sensor Circuit Slow Response (Bank 1 Sensor 2); DTC P0156: Oxygen Sensor Circuit Malfunction (Bank 2 Sensor 2); DTC P0157: Oxygen Sensor Circuit Low Voltage (Bank 2 Sensor 2); DTC P0158: Oxygen Sensor Circuit High Voltage (Bank 2 Sensor 2); DTC P0159: Oxygen Sensor Circuit Slow Response (Bank 2 Sensor 2) . Then proceed to 6 "INSPECT ECM".
- If DTC P0607 and P0136, P0137, P0138, P0156, P0157 or P0158 are output, the output voltage of the heated oxygen sensor may remain close to 0 V or become high (around 1 V or more).
NEXT: Go to next step
- Inspect the P0136, P0137, P0138, P0156, P0157 or P0158 flow chart.
- INSPECT ECM
- Clear DTC. Refer to DTC CHECK / CLEAR .
- Stop the engine and wait for 30 minutes.
- Connect the Techstream to the DLC3.
- Start the engine and allow it to idle for 2 minutes.
- Turn the Techstream on.
- Enter the following menu: Powertrain / Engine and ECT / Trouble Codes.
- Check the DTCs.RESULT
Result Proceed to DTC is not output A P0607 is output B
B → See step 7
A → END
- REPLACE ECM. Refer to REMOVAL