Service Data [02/2014 - ]
VSC OFF Switch
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 6 (+) - 3 (E) | Switch pushed | Below 1 Ω |
| 6 (+) - 3 (E) | Switch not pushed | 10 kΩ or higher |
ABS MOTOR Relay
FOR ABS MTR NO. 1 RELAY
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (BM1) - 5 (+BM1) | Voltage is not applied between terminals 1 (MR1) and 2 (R1-) | 10 kΩ or higher |
| 3 (BM1) - 5 (+BM1) | Voltage is applied between terminals 1 (MR1) and 2 (R1-) | Below 1 Ω |
FOR ABS MTR NO. 2 RELAY
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (BM2) - 5 (+BM2) | Voltage is not applied between terminals 1 (MR2) and 2 (R2-) | 10 kΩ or higher |
| 3 (BM2) - 5 (+BM2) | Voltage is applied between terminals 1 (MR2) and 2 (R2-) | Below 1 Ω |
Stop Light Control Relay
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Voltage is not applied between terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 4 | Voltage is applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Voltage is applied between terminals 1 and 2 | Below 1 Ω |