DTC P060B: Internal Control Module A/D Processing Performance [08/2015 - 08/2019]: Procedure
- CHECK FOR DTC
- Clear the DTCs (Refer to DTC CHECK / CLEAR [08/2015 - 08/2019] ).
- Turn the ignition switch off.
- Disconnect the cable from the negative (-) battery terminal and wait for 1 minute.
- Connect the cable to the negative (-) battery terminal.
- Turn the ignition switch to ON.
- Check for DTCs.
OK
P060B is not output.
Result:
OK
CHECK FOR INTERMITTENT PROBLEMS
(Refer to CHECK FOR INTERMITTENT PROBLEMS [08/2015 - ] )
Result:
NG
REPLACE ECM
(Refer to REMOVAL [08/2015 - ] )