Test Procedure
-- Perform a preliminary check to verify the customers complaint. Refer to PRELIMINARY CHECK
Start diagnosis
-- Connect the scan tool.
-- Engine MUST be at room temperature.
-- Turn the ignition switch ON.
-- Using the scan tool, Check the ambient air temperature:
| Diagnostic text | Specified value | |||
|---|---|---|---|---|
| Ambient Air Temperature (AAT) Sensor | approx. ambient air temperature | |||
-- Turn the ignition switch OFF.
If the specified value was obtained:
-- Fault may be intermittent. Check for proper connection, damaged wiring or loose terminals.
If the specified value was Not obtained:
Checking internal resistance
-- Disconnect the Ambient Air Temperature Sensor -G17- electrical harness connector.
-- Using a multimeter, Check the Ambient Air Temperature Sensor -G17- terminals 1 to 2 for resistance.
Use the chart below for the specified values:
Specified values:
| AAT Temperature vs Resistance | ||
| Temp (C) | min. valueΩs | max. valueΩs |
| - 40 | 31811 | 37560 |
| - 35 | 22941 | 26863 |
| - 25 | 12415 | 14289 |
| - 15 | 6958 | 7880 |
| - 5 | 4036 | 4495 |
| 0 | 3120 | 3442 |
| 5 | 2422 | 2655 |
| 15 | 1519 | 1623 |
| 25 | 968 | 1031 |
| 35 | 629 | 676 |
| 45 | 419 | 455 |
| 55 | 286 | 314 |
| 65 | 195 | 217 |
| 75 | 136 | 155 |
If the specified values were Not obtained:
-- Replace the Ambient Air Temperature Sensor -G17-. Refer to the Repair Information.
If the specified values are obtained, continue the test according to the following table: