B188D - Power Liftgate Control Circuit 1 Low: Notes
For a complete wiring diagram, refer to appropriate Wiring Diagram
- >>When Monitored:<< Whenever the power liftgate is power opening or closing.
- >>Set Condition:<< When the power liftgate module senses voltage less than 1.5 volts on the liftgate open driver circuit, prior to starting a power cycle, this code will set.
| Possible Causes |
|---|
| Q88 LIFTGATE OPEN DRIVER CIRCUIT SHORT TO GROUND |
| Q88 LIFTGATE OPEN DRIVER CIRCUIT SHORT to Q89 LIFTGATE CLOSE DRIVER CIRCUIT |
| Q89 LIFTGATE CLOSE DRIVER CIRCUIT SHORT TO GROUND |
| POWER LIFTGATE DRIVE UNIT SHORT |
| POWER LIFTGATE MODULE |
Test Step 1 - DTC Present
- With the scan tool, record DTCs.
- Erase DTCs.
- Turn the ignition OFF, wait 10 seconds, then turn the ignition ON.
- If possible, operate the liftgate several times.
- With the scan tool, check for DTCs.
Does the scan tool display B188D - Power Liftgate Control Circuit 1 Low?
Yes
- Go to Test Step 2 Test Step 2 - Liftgate Open Driver Circuit Short to Ground
No
- Using the wiring diagram/schematic as a guide, inspect the wiring and connectors for an intermittent condition.
- Perform the Body Verification Test. Refer to BODY VERIFICATION TEST .