B18E5 - Power Liftgate Front Zone Switch - Stuck: Notes
For a complete wiring diagram, refer to appropriate Wiring Diagram
- >>When Monitored:<< Whenever the power liftgate module is awake.
- >>Set Condition:<< When the power liftgate module senses the liftgate switch sense circuit active (2.0 to 3.0 volts) for longer than 15 seconds, this code will set.
| Possible Causes |
|---|
| G25 LIFTGATE SWITCH SENSE CIRCUIT PARTIALLY SHORT TO GROUND |
| LIFTGATE SWITCH STUCK |
| POWER LIFTGATE MODULE |
Test Step 1 - DTC Present
- With the scan tool, record DTCs.
- Erase DTCs.
- Turn the ignition OFF, wait 10 seconds, then turn the ignition ON.
- Operate the liftgate several times from the overhead switch.
- With the scan tool, check for DTCs.
Does the scan tool display B18E5 - Power Liftgate Front Zone Switch Stuck?
Yes
- Go to Test Step 2 Test Step 2 - Liftgate Release Switch Stuck
No
- Using the wiring diagram/schematic as a guide, inspect the wiring and connectors for an intermittent condition.
- Perform the Body Verification Test. Refer to BODY VERIFICATION TEST .