B1963 - Power Liftgate Strut Performance: Notes
For a complete wiring diagram, refer to appropriate Wiring Diagram
- >>When Monitored:<< One second after the liftgate completes a power opening operation.
- >>Set Condition:<< If the liftgate starts to drop after a complete opening operation, the power liftgate module will set this code.
| Possible Causes |
|---|
| WEAK STRUTS |
| POWER LIFTGATE DRIVE UNIT |
Test Step 1 - DTC Present
- With the scan tool, record DTCs and any liftgate inhibitors.
- Erase DTCs.
- Turn the ignition OFF, wait 10 seconds, then turn the ignition ON.
- Operate the liftgate several times.
- With the scan tool, check for DTCs.
Does the scan tool display B1963 - Power Liftgate Strut Performance?
Yes
- Go to Test Step 2 Test Step 2 - Weak Struts
No
- Ensure there is no intermittent binding or cold weather condition which may have caused this code to set.
- Perform the Body Verification Test. Refer to BODY VERIFICATION TEST .