Test Step 4 - Power Liftgate Drive Unit - Full Open Switch
- Disconnect the power liftgate drive unit harness connector.
- Measure the voltage between the liftgate full open switch sense circuit and sensor ground in the drive unit connector.
- While measuring the voltage, wiggle the harness from the PLG module to the drive unit connector.
Is the voltage constantly above 4.6 volts?
Yes
- Replace the power liftgate drive unit. Refer to POWER LIFTGATE DRIVE UNIT .
- Perform the Body Verification Test. Refer to BODY VERIFICATION TEST .
No
Test Step 5 - Liftgate Full Open Switch Sense Circuit Short to Ground
- Turn the ignition OFF.
- Disconnect the power liftgate module C1 harness connector.
- Measure the resistance between ground and the liftgate full open switch sense circuit in the power liftgate drive unit harness connector.
Is the resistance less than 10k ohms?
Yes
- Repair the liftgate full open switch sense circuit for a short to ground.
- Perform the Body Verification Test. Refer to BODY VERIFICATION TEST .
No