Test Procedure
-- Perform a preliminary check to verify the customers complaint. Refer to PRELIMINARY CHECK
Start diagnosis
-- If you have DTC's for the Reducing Agent Pump Heater (Heating Circuit 2) -Z103- please click the following link. If not continue on to the next step in this procedure.
| Value | Cause | Test |
|---|---|---|
| DTC's for Reducing Agent Pump Heater Z103: | Component Check | Reducing Agent Pump Heater (Heating Circuit 2) -Z103- Checking Resistance |
-- Disconnect the Reducing Agent Pump -V437- / Reducing Agent Pump Heater -Z103- -4- electrical harness connector.
-- Switch the ignition On.
-- Using a multimeter, measure the voltage between electrical harness connector T5n. Refer to Wiring Diagrams for circuit details.
| Reducing Agent Pump -V437- / Reducing Agent Pump Heater -Z103- electrical harness connector T5n terminal: | Reducing Agent Pump -V437- / Reducing Agent Pump Heater -Z103- electrical connector T5n terminals: |
|---|---|
| - | 4 |
Specified value: Battery voltage
-- Switch the ignition Off.
Continue test according to the following table:
| Value | Cause | Test |
|---|---|---|
| If the specified value was not obtained: | Open or shorted circuit | Checking Wiring |
| If the specified value was obtained: | Check reference signal circuit | Checking Wiring |