Monitor-ID $A2: Misfire Cylinder 1 Data
-- Connect the scan tool.
-- Start the engine and run at idle.
-- Select "Diagnostic Mode 06: Check test the results of components that are not continuously monitored".
Select "Monitor-ID $A2".
-- Select the desired "Test-ID".
-- Check specified values at idle.
| Test-ID | DTC | Component or System | Min. | Max. | Additional Information |
| $0B | P0301 | Cylinder 1 data averaged during last 10 drive cycles. | 0.000 | 65535 | Refer to DTC P0301 in the DTC table Engine Control Module --, 2015 MY => . |
| $0C | P0301 | Cylinder 1 data current driving cycle. | 0.000 | 65535 | Refer to DTC P0301 in the DTC table Engine Control Module --, 2015 MY => . |
-- Switch the ignition Off.
-- If any of the components or systems fail to meet the specified values, refer to Diagnostic Mode 03: Interrogating Fault Memory to check for stored DTCs or the corresponding diagnostic repair procedure.