Engine/Motor Control Module --, 2021 MY
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| catalyst heating fuel volume regulator control relative fuel mass | not active active 5.02...249.98 | [%] | |||||||||
| Fuel Volume Regulator HP Control | P01C8 - Fuel Rail/System Pressure - Too Low Bank 2 | functional check | filtered fuel pressure controller output | > 1.20 | [MPa] | time after engine start | > 5.0 | [s] | 7.5 [s] multiple | 2 DCY |
|
| time after fuel cut off | > 1.5 | [s] | |||||||||
| fuel cut off | not active | ||||||||||
| catalyst heating | not active | ||||||||||
| fuel volume regulator control | active | ||||||||||
| relative fuel mass | 5.02...249.98 | [%] | |||||||||
| Cold Start Monitoring | P053F - Cold Start Fuel Pressure Performance Bank 1 | functional check | filtered diff. target pressure vs. actual pressure | < -2.50 | [MPa] | time after engine start | > 5.0 | [s] | 5.5 [s] multiple | 2 DCY |
|
| Fuel Volume Regulator HP Control | fuel cut off time after fuel cut off catalyst heating fuel volume regulator control relative fuel mass | not active> 1.5 active active 5.02...249.98 | [s][%] | ||||||||
| P053F - Cold Start Fuel Pressure Performance Bank 1 | functional check | filtered diff. target pressure vs. actual pressure | > 4.00 | [MPa] | time after engine start | > 5.0 | [s] | 4.0 [s] multiple | 2 DCY |
|
|
| fuel cut off time after fuel cut off catalyst heating fuel volume regulator control relative fuel mass | not active> 1.5 active active 5.02...249.98 | [s][%] | |||||||||
| Fuel Rail Pressure (FRP) Sensor | P0190 - Fuel Rail Pressure Sensor Circuit Bank 1 | out of range high | signal voltage | > 4.70 | [V] | 0.5 [s] continuous | 2 DCY |
|
|||
| P0192 - Fuel Rail Pressure Sensor Circuit Low Bank 1 | out of range low | signal voltage | < 0.30 | [V] | 0.5 [s] continuous | 2 DCY |
|
||||
| Fuel Rail Pressure (FRP) Sensor | P0191 - Fuel Rail Pressure Sensor Circuit Range/Performance Bank 1 | out of range high | actual pressure | > 49.25 | [MPa] | sensor voltage | valid | 2.0 [s] continuous | 2 DCY |
|
|
| P0191 - Fuel Rail Pressure Sensor Circuit Range/Performance Bank 1 | out of range low | actual pressure | < 0.100 | [MPa] | engine speed fuel pump | 760...7000 commanded on | [RPM] | 2.0 [s] continuous | 2 DCY |
|
|
| Fuel Rail Pressure (FRP) Sensor | P01C4 - Fuel Pressure Sensor "A" Circuit Range/Performance | rationality check inappropriately | general: | general: |
|
||||||
| low (negative offset) | rail pressure bank 1 @ engine | < 0.10 | [MPa] | ECT downstream engine @ | > 54 | [°C] | 0 [s] | 2 DCY | |||
| start | engine shut- off | once / DCY | |||||||||
| and | modeled ECT @ engine shutoff | > 95 | [°C] | ||||||||
| choice of: | ECT downstream engine @ start | <= 35 | [°C] | ||||||||
| fuel system too rich @ part load | not calibrated | [%] | diff. between ECT downstream | > -9.8; <= 9.8 | [K] | ||||||
| engine @ start and IAT | |||||||||||
| downstream CAC | |||||||||||
| or | engine off time | >= 25000.0 | [s] | ||||||||
| fuel system too rich @ idle | not calibrated | [%] | engine speed | 0 | [RPM] | ||||||
| or | diff. between AAT and ECT | -10.0...10.0 | [K] | ||||||||
| downstream engine @ start | |||||||||||
| fault fuel system too rich @ part | not calibrated | diff. between AAT and IAT | -9.8...9.8 | [K] | |||||||
| load | downstream CAC @ start | ||||||||||
| or | and | ||||||||||
| fault fuel system too rich @ idle | not calibrated | conditions optional | |||||||||
| or | lambda control | active | |||||||||
| misfire fault | not calibrated | DFI mode | active | ||||||||
| or | catalyst heating | not active | |||||||||
| sum of lambda adaptation and | < 0.70 | [-] | ECT downstream engine | >= 50 | [°C] | ||||||
| lambda controller deviation | |||||||||||
| or | IAT downstream CAC | <= 90 | [°C] | ||||||||
| lambda control | not calibrated | engine torque | < 45.00 | [%] | |||||||
| lambda set point | 0.95...1.05 | [-] | |||||||||
| additional conditions: | |||||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| no additional conditions | |||||||||||
| calibrated | |||||||||||
| P01C4 - Fuel Pressure Sensor "A" Circuit Range/Performance | rationality check inappropriately | general: | general: |
|
|||||||
| high (positive offset) | rail pressure bank 1 @ engine | > 1.50 | [MPa] | ECT downstream engine @ | > 54 | [°C] | 0 [s] | 2 DCY | |||
| start | engine shut- off | once / DCY | |||||||||
| and | modeled ECT @ engine shutoff | > 95 | [°C] | ||||||||
| choice of: | ECT downstream engine @ start | <= 35 | [°C] | ||||||||
| fuel system too lean @ part load | not calibrated | [%] | diff. between ECT downstream | > -9.8; <= 9.8 | [K] | ||||||
| engine @ start and IAT | |||||||||||
| downstream CAC | |||||||||||
| or | engine off time | >= 25000.0 | [s] | ||||||||
| fuel system too lean @ idle | not calibrated | [%] | engine speed | 0 | [RPM] | ||||||
| or | diff. between ECT downstream | -10.0...10.0 | [K] | ||||||||
| engine @ start and AAT | |||||||||||
| fault fuel system too lean @ part | not calibrated | diff. between AAT and IAT | -9.8...9.8 | [K] | |||||||
| load | downstream CAC @ start | ||||||||||
| or | and | ||||||||||
| fault fuel system too lean @ idle | not calibrated | conditions optional | |||||||||
| or | lambda control | active | |||||||||
| misfire fault | not calibrated | DFI mode | active | ||||||||
| or | catalyst heating | not active | |||||||||
| sum of lambda adaptation and | > 1.30 | [-] | ECT downstream engine | >= 50 | [°C] | ||||||
| lambda controller deviation | |||||||||||
| or | IAT downstream CAC | <= 90 | [°C] | ||||||||
| lambda control | not calibrated | engine torque | < 45.00 | [%] | |||||||
| lambda setpoint | 0.95...1.05 | [-] | |||||||||
| additional conditions: | |||||||||||
| no additional conditions | |||||||||||
| calibrated | |||||||||||
| High PCV Purge Load due to Oil Dilution | --- | ratio modeled fuel mass evaporation out of oil to actual necessary fuel mass | > 0.08 | [-] | |||||||
| modeled oil temperature | > 0 | [°C] | |||||||||
| or | |||||||||||
| ratio on calculated fuel mass evaporation out of oil to actual necessary fuel mass | > 0.25 | [-] | |||||||||
| modeled oil temperature | > 0 | [°C] | |||||||||
| conditions for fast fuel trim | --- | O2S front fault suspicion from lambda control - case 1: lambda controller at min limit | |||||||||
| O2S Front Offset Adaptation | 1st lambda control loop O2S front setpoint O2S front signal O2S rear voltage O2S rear case 2: lambda controller at max limit 1st lambda control loop O2S front setpoint O2S front signal O2S rear voltage O2S rear conditions for accumulation of | at min limit 1.00< 1.0< 0.4 ready at max limit 1.00> 1.0> 0.6 ready | [-][-] [V][-][-] [V] | ||||||||
| exhaust gas mass for steady state O2S rear O2S front setpoint catalyst purge engine speed | ready 1.00 not active> 1000 | [-][RPM] | |||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| with delay time | 2.0 | [s] | |||||||||
| fuel cut off | not active | ||||||||||
| ECT | > 43 | [°C] | |||||||||
| catalyst reheating | not calibrated | ||||||||||
| catalyst heating during cold Start | not active | ||||||||||
| catalyst heating with AIR | not active | ||||||||||
| engine load gradient | < 100.01 | [%/CAMr | |||||||||
| ev] | |||||||||||
| engine load cycle | < 8.00 | [-] | |||||||||
| engine load | > 12.00 | [%] | |||||||||
| engine state | not pre-drive or post-drive | ||||||||||
| AIR | not active | ||||||||||
| AIR system diagnosis | not active | ||||||||||
| accumulation of exhaust gas | |||||||||||
| mass for steady state after | |||||||||||
| fuel cut off with catalyst purge | |||||||||||
| integrated exhaust gas mass | > 285.0 | [g] | |||||||||
| (steady state detection) | |||||||||||
| accumulation of exhaust gas | |||||||||||
| mass for steady state after | |||||||||||
| fuel cut off without catalyst | |||||||||||
| purge | |||||||||||
| integrated exhaust gas mass | > 285.0 | [g] | |||||||||
| (steady state detection) | |||||||||||
| conditions for accumulation of | |||||||||||
| exhaust gas mass for | |||||||||||
| adaptation | |||||||||||
| O2S front response monitoring | not calibrated | ||||||||||
| in current DCY | |||||||||||
| or | |||||||||||
| O2S rear offset monitor fault | not calibrated | ||||||||||
| suspicion (target voltage not | |||||||||||
| reached) | |||||||||||
| or | |||||||||||
| O2S front fault suspicion from | not calibrated | ||||||||||
| lambda control | |||||||||||
| for time | not calibrated | [s] | |||||||||
| modeled EGT | 400...900 | [°C] | |||||||||
| for time | > 2.0 | [s] | |||||||||
| exhaust gas mass flow | 20.00...160.00 | [kg/h] | |||||||||
| or | |||||||||||
| exhaust gas mass flow | 10.00...20.00 | [kg/h] | |||||||||
| within time | < 8.0 | [s] | |||||||||
| O2S front | ready | ||||||||||
| H2 correction of O2S rear | not calibrated | [V] | |||||||||
| voltage | |||||||||||
| O2S front offset monitoring in | not calibrated | ||||||||||
| current DCY | |||||||||||
| catalyst damaging misfire | not detected | ||||||||||
| scavenging-rate | < 1.03 | [-] | |||||||||
| and | |||||||||||
| lambda control | not calibrated | ||||||||||
| split factor DFI/MFI | not calibrated | ||||||||||
| lambda control | closed loop | ||||||||||
| for time | >= 2.0 | [s] | |||||||||
| case 1: lambda controller not | |||||||||||
| at min or max limit | |||||||||||
| O2S rear | ready | ||||||||||
| O2S rear Control Loop (i-part, | not calibrated | ||||||||||
| referenced) | |||||||||||
| for time | not calibrated | [s] | |||||||||
| or | |||||||||||
| O2S rear Control Loop (p-part, | active | ||||||||||
| referenced) | |||||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| for time | >= 30.0 | [s] | |||||||||
| case 2: lambda controller at | |||||||||||
| min or max limit | |||||||||||
| O2S front fault suspicion from | active | ||||||||||
| lambda control | |||||||||||
| above both cases for time | >= 2.0 | [s] | |||||||||
| accumulation of exhaust gas | |||||||||||
| mass for adaptation | |||||||||||
| integrated exhaust gas mass | 70.0...90.0 | [g] | |||||||||
| (adaptation check) | |||||||||||
| reset of exhaust gas mass for | |||||||||||
| adaptation | |||||||||||
| check for adaptation step | finished | ||||||||||
| or | |||||||||||
| conditions for accumulation of | not fulfilled | ||||||||||
| exhaust gas mass for adaptation | |||||||||||
| final conditions: fault | |||||||||||
| debounce - case 1 | |||||||||||
| number of checks for adaptation | >= 1.00 | [-] | |||||||||
| in row | |||||||||||
| change of ABS adapted i-part of | <= 0.30 | [%] | |||||||||
| 2nd lambda control loop (O2S | |||||||||||
| front offset) at each check | |||||||||||
| (adaptation finished) | |||||||||||
| or | |||||||||||
| low pass filtered ABS sum of | > 0 | [%] | |||||||||
| control value and control error of | |||||||||||
| 2nd lambda control loop at each | |||||||||||
| check (adoption demand in | |||||||||||
| fault direction) | |||||||||||
| with filter time | 14.0 | [s] | |||||||||
| case 2 | |||||||||||
| number of total checks for | >= 2.00 | [-] | |||||||||
| adaptation | |||||||||||
| final conditions: heal | |||||||||||
| debounce | |||||||||||
| number of checks for adaptation | >= 1.00 | [-] | |||||||||
| in row | |||||||||||
| change of ABS adapted i-part of | <= 0.30 | [%] | |||||||||
| 2nd lambda control loop (O2S | |||||||||||
| front offset) at each check | |||||||||||
| (adaptation finished) | |||||||||||
| conditions for O2S rear lambda | --- | i-part global balance primary | |||||||||
| control loop (i-part) | O2S rear control enable | ||||||||||
| conditions | |||||||||||
| O2S rear Control Loop (i-part) | EVAP monitoring | not active | |||||||||
| scavenging rate | < 1.05 | [-] | |||||||||
| band width of lambda control | 0 | [-] | |||||||||
| deviation | |||||||||||
| ECT | > 55 | [°C] | |||||||||
| catalyst heating (lambda split) | not calibrated | ||||||||||
| relative fuel mass @ EVAP | not calibrated | [-] | |||||||||
| purge | |||||||||||
| filtered engine load gradient | < -4.01...4.01 | [%/CAMr | |||||||||
| ev] | |||||||||||
| for filtered time | 0.1 | [s] | |||||||||
| i-part balance primary O2S | |||||||||||
| rear control enable condition | |||||||||||
| lambda control | no limit | ||||||||||
| primary O2S rear control @ | |||||||||||
| open loop (limp home mode) | |||||||||||
| fuel injector power stage error | not calibrated | ||||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| fuel injection time lower threshold O2S front i-part general conditions O2S rear Control Loop (p-part, referenced) primary O2S rear control @ open loop (limp home mode) i-part global O2S front control enable conditions i-part global balance primary O2S rear control enable conditions engine speed engine load idle speed (without fuel cut off) for timei-part balance primary O2S rear control enable condition | not calibrated not calibrated active not active enabled 1200...652021.75...165.00 not calibrated not calibrated | [rpm][%][s] | |||||||||
| i-part balance primary O2S rear control enable condition i-part system primary O2S rear | enabled | ||||||||||
| control enable conditions | |||||||||||
| exhaust gas mass of O2S rear Control Loop (p-part, referenced) catalyst temperature conditions for accumulation exhaust gas mass i-part global balance primary O2S rear control enable conditions i-part balance primary O2S rear control enable condition H2 protection primary O2S rear control O2S rear catalyst heating Exhaust gas mass after first start | > 30.0400...1000 enabled enabled not calibrated ready not calibrated> 29.9 | [g][°C][g] | |||||||||
| exhaust gas mass after restart | > 29.9 | [g] | |||||||||
| conditions for O2S rear lambda | --- | p-part primary O2S rear | |||||||||
| control loop (p-part) | control enable conditions | ||||||||||
| O2S rear Control Loop (p-part) | lambda control | no limit | |||||||||
| lambda control | closed loop | ||||||||||
| primary O2S rear control @ | |||||||||||
| open loop (limp home mode) | |||||||||||
| fuel injector power stage error | not detected | ||||||||||
| fuel injection time lower threshold | not detected | ||||||||||
| O2S front | not ready | ||||||||||
| p-part global primary O2S rear | |||||||||||
| control enable conditions | |||||||||||
| catalyst heating | not calibrated | ||||||||||
| EVAP monitoring | not calibrated | ||||||||||
| misfire | not detected | ||||||||||
| engine speed | 1080...8000 | [RPM] | |||||||||
| engine load | 0.00...174.75 | [%] | |||||||||
| p-part balance primary O2S | |||||||||||
| rear control enable conditions | |||||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| O2S rear lambda control loop @low-temperature mode | active | ||||||||||
| or | |||||||||||
| O2S rear | ready | ||||||||||
| p-part primary O2S rear control enable conditions | enabled | ||||||||||
| or | |||||||||||
| primary O2S rear control @open loop (limp home mode) | enabled | ||||||||||
| p-part system primary O2S | |||||||||||
| rear control enable conditions | |||||||||||
| catalyst temperature | 300...1262 | [°C] | |||||||||
| conditions for accumulation | |||||||||||
| exhaust gas mass | |||||||||||
| O2S front lambda setpoint | 1.00 | [-] | |||||||||
| catalyst purge (rich condition detected) | not active | ||||||||||
| p-part primary O2S rear control enable conditions | enabled | ||||||||||
| or | |||||||||||
| primary O2S rear control @open loop (limp home mode) | enabled | ||||||||||
| exhaust gas mass | > 0.0 | [g] | |||||||||
| conditions for active lambda | --- | general conditions | |||||||||
| diagnosis | |||||||||||
| Active Lambda Diagnosis | time after engine start | not calibrated | [s] | ||||||||
| or | |||||||||||
| modeled catalyst temperature | not calibrated | [°C] | |||||||||
| or | |||||||||||
| integrated air mass | not calibrated | [kg] | |||||||||
| integrated heat energy | > 730.00...2000.00 | [kJ] | |||||||||
| O2S front | ready | ||||||||||
| O2S front offset error suspicion | not detected | ||||||||||
| or | |||||||||||
| O2S front dynamic error | not detected | ||||||||||
| suspicion | |||||||||||
| MAF condition in case of O2S | |||||||||||
| offset suspicion | |||||||||||
| exhaust gas mass flow | 20.00...150.00 | [kg/h] | |||||||||
| O2S rear | ready | ||||||||||
| integrated air mass after O2S | >= 0.02 | [kg] | |||||||||
| ready | |||||||||||
| modeled EGT at O2S rear | > 200 | [°C] | |||||||||
| difference between actual O2S | < 65.0 | [K] | |||||||||
| ceramic temp. and O2S ceramic | |||||||||||
| temp. setpoint | |||||||||||
| time after fuel cut off | > 5.0 | [s] | |||||||||
| lambda setpoint | 0.99...1.01 | [-] | |||||||||
| for | |||||||||||
| integrated air mass | >= 0.00 | [kg] | |||||||||
| engine speed | 1040...2960 | [RPM] | |||||||||
| vehicle speed | > 5 | [km/h] | |||||||||
| engine load | > 12.00 | [%] | |||||||||
| AAT | not calibrated | [°C] | |||||||||
| ECT downstream engine | > -48 | [°C] | |||||||||
| BARO | > 0.00 | [kPa] | |||||||||
| camshaft @ modified valve lift | not calibrated | [-] | |||||||||
| gear shifting | not calibrated | [-] | |||||||||
| for time | not calibrated | [s] | |||||||||
| delay time for interpolation | not calibrated | [s] | |||||||||
| (secondary fuel) | |||||||||||
| fuel adaptation (since last reset) | not calibrated | ||||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| acceleration enrichment / | not calibrated | ||||||||||
| deceleration enleanment | |||||||||||
| for time | not calibrated | [s] | |||||||||
| fuel injector shut off (selective, in | not calibrated | ||||||||||
| case of fault detection) | |||||||||||
| for time | not calibrated | [s] | |||||||||
| delay after cylinder deactivation | not calibrated | [s] | |||||||||
| (CD) transition | |||||||||||
| alternative EVAP condition 1 | |||||||||||
| integrated EVAP purge mass | > 5.0 | [g] | |||||||||
| since last purge stop | |||||||||||
| ratio fuel mass from EVAP purge | <= 0.50 | [-] | |||||||||
| system to fuel mass through | |||||||||||
| injectors | |||||||||||
| EVAP purge adaptation value | <= 2.00 | [-] | |||||||||
| or | |||||||||||
| alternative EVAP condition 2 | |||||||||||
| EVAP purge mass into intake | <= 4.00 | [kg/h] | |||||||||
| manifold | |||||||||||
| or | |||||||||||
| evap purge in limp-home mode | active | ||||||||||
| or | |||||||||||
| alternative EVAP condition 3 | |||||||||||
| evap purge | not active | ||||||||||
| scavenging | |||||||||||
| scavenging rate | < 1.05 | [-] | |||||||||
| for | |||||||||||
| integrated air mass | > 0.02 | [kg] | |||||||||
| lower range window | |||||||||||
| exhaust gas mass flow, lower | 20.50...137.50 | [kg/h] | |||||||||
| range to activate diagnosis | |||||||||||
| (narrow range) | |||||||||||
| exhaust gas mass flow, lower | 18.00...140.00 | [kg/h] | |||||||||
| range during diagnosis (normal | |||||||||||
| range) | |||||||||||
| exhaust gas mass flow, lower | 15.50...140.00 | [kg/h] | |||||||||
| range during diagnosis | |||||||||||
| (extended range) | |||||||||||
| extended range only for time | <= 1.0 | [s] | |||||||||
| modeled EGT in catalyst system, | 440...835 | [°C] | |||||||||
| lower range to activate diagnosis | |||||||||||
| (narrow range, gasoline mode) | |||||||||||
| modeled EGT in catalyst system, | 425...850 | [°C] | |||||||||
| lower range during diagnosis | |||||||||||
| (normal range, gasoline mode) | |||||||||||
| modeled EGT in catalyst system, | not active | [°C] | |||||||||
| lower range during diagnosis | |||||||||||
| (normal range, CNG mode) | |||||||||||
| change of modeled catalyst | -15.0...25.0 | [K] | |||||||||
| temperature | |||||||||||
| upper range window | |||||||||||
| exhaust gas mass flow, upper | not calibrated | [kg/h] | |||||||||
| range to activate diagnosis | |||||||||||
| (narrow range) | |||||||||||
| exhaust gas mass flow, upper | not calibrated | [kg/h] | |||||||||
| range during diagnosis (normal | |||||||||||
| range) | |||||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| modeled EGT in catalyst system, | not calibrated | [°C] | |||||||||
| upper range to activate | |||||||||||
| diagnosis (narrow range, | |||||||||||
| gasoline mode) | |||||||||||
| modeled EGT in catalyst system, | not calibrated | [°C] | |||||||||
| upper range during diagnosis | |||||||||||
| (normal range, gasoline mode) | |||||||||||
| modeled EGT in catalyst system, | not active | [°C] | |||||||||
| upper range during diagnosis | |||||||||||
| (normal range, CNG mode) | |||||||||||
| change of modeled catalyst | not calibrated | [K] | |||||||||
| temperature | |||||||||||
| lower/upper range window | |||||||||||
| (conditions fulfilled) | |||||||||||
| catalyst temperature | > 350 | [°C] | |||||||||
| for time | > 90.0 | [s] | |||||||||
| for integrated exhaust gas mass | > 0.02 | [kg/h] | |||||||||
| flow | |||||||||||
| integrated air mass | >= 0.02 | [kg] | |||||||||
| change of exhaust gas mass | -15.00...40.00 | [kg/h] | |||||||||
| flow | |||||||||||
| with delay time | 1.0 | [s] | |||||||||
| lambda enable condition | |||||||||||
| monitor - only if | |||||||||||
| deviation between engine | < 0.03 | [-] | |||||||||
| nominal lambda value and | |||||||||||
| expected lambda @ sensor | |||||||||||
| position | |||||||||||
| monitoring stops if lambda | >= -2.00...2.00 | [%] | |||||||||
| deviation | |||||||||||
| with delay time | >= 1.5...4.0 | [s] | |||||||||
| or | |||||||||||
| monitoring stop events per DCY | >= 7.00 | [-] | |||||||||
| (monitoring stop disabled) | |||||||||||
| lambda control | not at min or max limit | ||||||||||
| lambda setpoint request | realized | ||||||||||
| conditions to switch from rich | |||||||||||
| to lean phase | |||||||||||
| actual lambda value | 0.80...0.99 | [-] | |||||||||
| for time | > 2.0 | [s] | |||||||||
| integrated exhaust gas mass | >= 0.01 | [kg] | |||||||||
| alternative condition 1 | |||||||||||
| O2S rear voltage | >= 0.85 | [V] | |||||||||
| or | |||||||||||
| alternative condition 2 | |||||||||||
| O2S rear voltage | >= 0.75 | [V] | |||||||||
| O2S rear voltage gradient | -0.15...0.10 | [V/s] | |||||||||
| MAF rich gas integral | >= 0.4 | [g] | |||||||||
| conditions to switch from lean | |||||||||||
| to rich phase | |||||||||||
| actual lambda value | 0.96...1.18 | [-] | |||||||||
| for time | > 2.0 | [s] | |||||||||
| integrated exhaust gas mass | >= 0.01 | [kg] | |||||||||
| alternative condition 1 | |||||||||||
| O2S rear voltage | <= 0.15 | [V] | |||||||||
| or | |||||||||||
| alternative condition 2 | |||||||||||
| O2S rear voltage | <= 0.15 | [V] | |||||||||
| O2S rear voltage gradient | 66.50...-66.50 | [V/s] | |||||||||
| MAF O2 integral | >= 0.2 | [g] | |||||||||
| Oxygen Sensor (O2S) front | P0133 - O2 Sensor Circuit Slow Response Bank 1 Sensor 1 | intrusive monitor | delayed response (arithmetic filter) | conditions for dynamic fault suspicion evaluation |
|
||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| O2S signal dynamic check | time @ lean to rich transition | not calibrated | [s] | dev. expected vs. measured lambda (high quality model) or dev. expected vs. measured lambda (low quality model) monitor entry conditions active lambda diagnosis (referenced) conditions for avoiding controller oscillations online identification (referenced) for arithmetic average value calculation number of checks required for valid result for EWMA-filter: K-factor minimum number of tests per DCY required step change detection will initiate multiple tests per DCY conditions for step change detection (delayed response) deviation between new measured value and old EWMA filtered value (delayed response) maximum tolerance to confirm filtered value (delayed response) or step change detection will initiate multiple tests per DCY conditions for step change detection (transition response) deviation between new measured value and old EWMA filtered value (transition response) maximum tolerance to confirm filtered value (transition response) further calculation conditions for EWMA filter number of checks for confirmation initial value of filtered value maximum number of checks per driving cycle | >= 3.00 | [-] | 20 [s] once / DCY | 1 DCY | |||
| or time @ rich to lean transition | not calibrated | [s] | >= 30.00 | [-] | |||||||
| slow transition (arithmetic filter) time @ lean to rich transition | not calibrated | [s] | checked | ||||||||
| or | |||||||||||
| time @ rich to lean transition | not calibrated | [s] | not calibrated | ||||||||
| delayed response (EWMA filter) time @ lean to rich transition | > 0.4 | [s] | not calibrated | [-] | |||||||
| or time @ rich to lean transition slow transition (EWMA filter) | > 0.4 | [s] | 0.251 | [-][-] | |||||||
| time @ lean to rich transition | > 0.4 | [s] | |||||||||
| or | > 0.3 | [s] | |||||||||
| time @ rich to lean transition | > 0.4 | [s] | 0.08 | [s] | |||||||
| delayed response (while avoiding controller oscillations) adaptation time @ lean to rich transition | not calibrated | [s] | |||||||||
| or | > 0.3 | [s] | |||||||||
| adaptation time @ rich to lean transition | not calibrated | [s] | 0.08 | [s] | |||||||
| slow transition (while avoiding | |||||||||||
| controller oscillations) | |||||||||||
| adaptation time @ lean to rich transition or adaptation time @ rich to lean transition delayed response and slow transition (while avoiding controller oscillations) sum of adaptation times (delay and slow response) @ lean to rich transition or sum of adaptation times (delay and slow response) @ rich to lean transition | not calibrated not calibrated not calibrated not calibrated | [s] [s] [s] [s] | 5.0005.00 | [-][-][-] | |||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Oxygen Sensor (O2S) front | P2195 - O2 Sensor Signal Biased/Stuck Lean Bank 1 Sensor 1 | out of range high | adapted I-part of 2nd lambda control loop (O2S front offset) | > 0.07 | [-] | condition for lambda split operation | 450 [s] multiple | 2 DCY |
|
||
| catalyst heating | not calibrated | ||||||||||
| pending fault from previous | |||||||||||
| DCY O2S front offset monitor | |||||||||||
| O2S rear Control Loop (i-part, referenced) | checked | ||||||||||
| for time | >= 10.0 | [s] | |||||||||
| O2S front offset adaptation (referenced), final conditions: fault debounce | fulfilled | ||||||||||
| additional conditions: | |||||||||||
| no additional conditions calibrated | |||||||||||
| P2196 - O2 Sensor Signal Biased/Stuck Rich Bank 1 Sensor 1 | out of range low | adapted I-part of 2nd lambda control loop (O2S front offset) | < -0.07 | [-] | condition for lambda split operation | 450 [s] multiple | 2 DCY |
|
|||
| catalyst heating | not calibrated | ||||||||||
| pending fault from previous | |||||||||||
| DCY O2S front offset monitor | |||||||||||
| O2S rear Control Loop (i-part, referenced) | checked | ||||||||||
| for time | >= 10.0 | [s] | |||||||||
| O2S front offset adaptation (referenced), final conditions: fault debounce | fulfilled | ||||||||||
| additional conditions: | |||||||||||
| no additional conditions calibrated | |||||||||||
| Oxygen Sensor (O2S) front | P223C - O2 Sensor Pumping Current Range/Performance Bank 1 | range check (detection of blackening protection) | voltage for fixed pump current duty cycle | > 2.00 | [V] | general conditions | 10 [events] continuous | 2 DCY |
|
||
| or | battery voltage | 10.70...16.10 | [V] | ||||||||
| voltage for fixed pump current duty cycle | <= -1.40 | [V] | or | ||||||||
| each criterion above must be | additional debouncing @ | ||||||||||
| fulfilled for minimum number | sufficient battery voltage | ||||||||||
| of checks (out of 16 | |||||||||||
| successive checks) | |||||||||||
| number of checks | >= 6.00 | [-] | battery voltage | < 10.70 | [V] | ||||||
| and | time delay | < 1.5 | [s] | ||||||||
| local pre-debounce | > 2.6 | [s] | and | ||||||||
| additional debouncing @ low | |||||||||||
| battery voltage | |||||||||||
| battery voltage | > 9.80 | [V] | |||||||||
| time delay | >= 0.1 | [s] | |||||||||
| O2S front conditions | |||||||||||
| pump current operation | active | ||||||||||
| counter for verification of the actual mode | > 20.00 | [-] | |||||||||
| diagnosis intervention | not requested | ||||||||||
| pump current package | valid | ||||||||||
| O2S front ceramic temperature | > 634 | [°C] | |||||||||
| or | |||||||||||
| O2S front heating | finished | ||||||||||
| O2S front heater control deviation | < 65.0 | [K] | |||||||||
| for time | >= 0.1 | [s] | |||||||||
| P223C - O2 Sensor Pumping Current Range/Performance Bank 1 | range check (positive or negative voltage drop @ internal resistor) | negative voltage drop deviation during pump current pulse for time | > 0.08>= 0.1 | [V][s] | general conditions battery voltage | 10.70...16.10 | [V] | 10 [events] continuous | 2 DCY |
|
|
| within | or | ||||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| number of negative overshoots | > 0.00 | [-] | additional debouncing @ | ||||||||
| sufficient battery voltage | |||||||||||
| or | battery voltage | < 10.70 | [V] | ||||||||
| positive voltage drop deviation | > 0.70 | [V] | time delay | < 1.5 | [s] | ||||||
| during pump current pulse | |||||||||||
| for time | >= 0.1 | [s] | and | ||||||||
| within | additional debouncing @ low | ||||||||||
| battery voltage | |||||||||||
| number of positive overshoots | > 0.00 | [-] | battery voltage | > 9.80 | [V] | ||||||
| time delay | >= 0.1 | [s] | |||||||||
| O2S front conditions | |||||||||||
| pump current operation | active | ||||||||||
| counter for verification of the | > 20.00 | [-] | |||||||||
| actual mode | |||||||||||
| diagnosis intervention | not requested | ||||||||||
| pump current package | valid | ||||||||||
| O2S front ceramic temperature | > 634 | [°C] | |||||||||
| or | |||||||||||
| O2S front heating | finished | ||||||||||
| O2S front heater control | < 65.0 | [K] | |||||||||
| deviation | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| Oxygen Sensor (O2S) front | P0131 - O2 Sensor Circuit Low Voltage Bank 1 Sensor 1 | circuit low (aborted RAM check) under voltage check @ sensor lines | voltage @ sensor pump current, virtual ground, trim current or nernst current | < -0.15 | [V] | battery voltage or battery voltage for time battery voltage conditions above must be fulfilled for time | not calibrated< 10.70< 1.5> 9.80; <= 16.10>= 0.1 | [V] [V] [s] [V] [s] | 5 [events] continuous | 2 DCY |
|
| P0131 - O2 Sensor Circuit Low Voltage Bank 1 Sensor 1 | circuit low (idle mode) under voltage check @ sensor lines | voltage @ sensor pump current, virtual ground, trim current or nernst current | < -0.15 | [V] | battery voltage or battery voltage for time battery voltage conditions above must be fulfilled for time | not calibrated< 10.70< 1.5> 9.80; <= 16.10>= 0.1 | [V] [V] [s] [V] [s] | 5 [events] multiple | 2 DCY |
|
|
| P0131 - O2 Sensor Circuit Low Voltage Bank 1 Sensor 1 | circuit low (switch-on or warm- | voltage drop | < - 0.2 | [V] | battery voltage or battery voltage for time battery voltage conditions above must be fulfilled for time | not calibrated < 10.70 < 1.5 > 9.80; <= 16.10 | [V] [V] [s] [V] | 5 [events] multiple | 2 DCY |
|
|
| up mode) voltage check @ sensor lines | |||||||||||
| >= 0.1 | [s] | ||||||||||
| Oxygen Sensor (O2S) front | P0132 - O2 Sensor Circuit High Voltage Bank 1 Sensor 1 | circuit high (aborted RAM check) | voltage @ ground resistor | > 4.0 | [V] | battery voltage | not calibrated | [V] | 5 [events] continuous | 2 DCY |
|
| over voltage check @ sensor lines | or voltage @ sensor pump current, virtual ground, trim current or nernst current | > 9.1...10.3 | [V] | or battery voltage for time battery voltage | < 10.70< 1.5> 9.80; <= 16.10 | [V] [s] [V] | |||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| P0132 - O2 Sensor Circuit High Voltage Bank 1 Sensor 1 | circuit high (idle mode) over voltage check @ sensor lines | voltage @ sensor pump current, virtual ground, trim current or nernst current | > 9.1...10.3 | [V] | battery voltage or battery voltage | not calibrated< 10.70 | [V] [V] | 5 [events] multiple | 2 DCY |
|
|
| for time | < 1.5 | [s] | |||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| P0132 - O2 Sensor Circuit High Voltage Bank 1 Sensor 1 | circuit high (switch-on or warm-up mode) | voltage drop | > 0.2 | [V] | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY |
|
|
| voltage check @ sensor lines | or | ||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| P0132 - O2 Sensor Circuit High Voltage Bank 1 Sensor 1 | circuit high (aborted RAM check @ warm-up mode) | voltage @ sensor pump current, virtual ground, trim current ornernst current | > 9.1...10.3 | [V] | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY |
|
|
| overvoltage @ sensor lines | or | or | |||||||||
| O2S ceramic temperature | > 634 | [°C] | battery voltage | < 10.70 | [V] | ||||||
| no open load detected within | for time | < 1.5 | [s] | ||||||||
| measured calibration resistance @ pump cell | >= 164.00 | [Ohm] | battery voltage | > 9.80; <= 16.10 | [V] | ||||||
| and | conditions above must be | ||||||||||
| fulfilled | |||||||||||
| measured calibration resistance @ nernst cell | >= 164.00 | [Ohm] | for time | >= 0.1 | [s] | ||||||
| Oxygen Sensor (O2S) front | P2243 - O2 Sensor Reference Voltage Circuit/Open Bank 1 Sensor 1 | open circuit (aborted RAM check) | ASIC operation | aborted | battery voltage | not calibrated | [V] | 5 [events] continuous | 2 DCY |
|
|
| circuit continuity check @ normal mode | orbattery voltage | < 10.70 | [V] | ||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| O2S heating up phase | completed | ||||||||||
| or | |||||||||||
| O2S ceramic temperature | > 634 | [°C] | |||||||||
| P2243 - O2 Sensor Reference Voltage Circuit/Open Bank 1 Sensor 1 | open circuit (not idle mode) | nernst voltage | > 1.80 | [V] | battery voltage | not calibrated | [V] | 5 [events] continuous | 2 DCY |
|
|
| circuit continuity check @ pump Current operation | or battery voltage | < 10.70 | [V] | ||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| O2S heating up phase | completed | ||||||||||
| or | |||||||||||
| O2S ceramic temperature | > 634 | [°C] | |||||||||
| P2243 - O2 Sensor Reference Voltage Circuit/Open Bank 1 Sensor 1 | open circuit (warm-up mode) | measured calibration resistance @ pump cell | >= 164.00 | [Ohm] | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY |
|
|
| nernst and pump cell transition check | and measured calibration resistance @ nernst cell | < 164.00 | [Ohm] | or battery voltage for time | < 10.70< 1.5 | [V][s] | |||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| O2S heating up phase | completed | ||||||||||
| or | |||||||||||
| O2S ceramic temperature | > 634 | [°C] | |||||||||
| P2243 - O2 Sensor Reference Voltage Circuit/Open Bank 1 Sensor 1 | open circuit (aborted RAM check @ warm-up mode) | ASIC operation | aborted | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY |
|
||
| circuit continuity check @ warm- | or | ||||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| up mode | battery voltage | < 10.70 | [V] | ||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| O2S heating up phase | completed | ||||||||||
| or | |||||||||||
| O2S ceramic temperature | > 634 | [°C] | |||||||||
| Oxygen Sensor (O2S) front | P2237 - O2 Sensor Positive Current Control Circuit/Open Bank 1 Sensor 1 | open circuit (aborted RAM check) | ASIC operation | aborted | battery voltage | not calibrated | [V] | 5 [events] continuous | 2 DCY |
|
|
| circuit continuity check @normal mode | orbattery voltage | < 10.70 | [V] | ||||||||
| for time | < 1.5 | [s] | |||||||||
| or | |||||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| O2S heating up phase | completed | ||||||||||
| or | |||||||||||
| O2S ceramic temperature | > 634 | [°C] | |||||||||
| P2237 - O2 Sensor Positive Current Control Circuit/Open Bank 1 Sensor 1 | open circuit (warm-up mode) | measured calibration resistance @ pump cell | < 164.00 | [Ohm] | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY |
|
|
| nernst and pump cell transition check | and measured calibration resistance @ nernst cell | >= 164.00 | [Ohm] | orbattery voltage for time | < 10.70< 1.5 | [V][s] | |||||
| or | |||||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| O2S heating up phase | completed | ||||||||||
| or | |||||||||||
| O2S ceramic temperature | > 634 | [°C] | |||||||||
| Oxygen Sensor (O2S) front | P2251 - O2 Sensor Negative Current Control Circuit/Open Bank 1 Sensor 1 | open circuit (normal ASIC operation) | O2S front heater control deviation | >= 65.0 | [K] | battery voltage | not calibrated | [V] | 5 [events] continuous | 2 DCY |
|
| circuit continuity check @ normal mode | within voltage pump cell | < -0.40 | [V] | or battery voltage | < 10.70 | [V] | |||||
| for time | >= 0.1 | [s] | for time | < 1.5 | [s] | ||||||
| or | battery voltage | > 9.80; <= 16.10 | [V] | ||||||||
| O2S front heater control deviation | < 65.0 | [K] | conditions above must be fulfilled | ||||||||
| within | for time | >= 0.1 | [s] | ||||||||
| voltage pump cell | < -0.08 | [V] | O2S heating up phase | completed | |||||||
| for time | >= 0.1 | [s] | or | ||||||||
| O2S ceramic temperature | > 634 | [°C] | |||||||||
| P2251 - O2 Sensor Negative Current Control Circuit/Open Bank 1 Sensor 1 | open circuit (aborted RAM check) | ASIC operation | aborted | battery voltage | not calibrated | [V] | 5 [events] continuous | 2 DCY |
|
||
| circuit continuity check @ normal mode | orbattery voltage | < 10.70 | [V] | ||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| O2S heating up phase | completed | ||||||||||
| or | |||||||||||
| O2S ceramic temperature | > 634 | [°C] | |||||||||
| P2251 - O2 Sensor Negative Current Control Circuit/Open Bank 1 Sensor 1 | open circuit (warm-up mode) | measured calibration reresistance @ pump cell | < 164.00 | [Ohm] | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY |
|
|
| nernst and pump cell transition check | and measured calibration resistance @ nernst cell | < 164.00 | [Ohm] | orbattery voltage for time | < 10.70< 1.5 | [V][s] | |||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| O2S heating up phase | completed | ||||||||||
| or | |||||||||||
| O2S ceramic temperature | > 634 | [°C] | |||||||||
| P2251 - O2 Sensor Negative Current Control Circuit/Open Bank 1 Sensor 1 | open circuit (aborted RAM check @ warm-up mode) | ASIC operation | aborted | battery voltage | not calibrated | [V] | 5 [events] multiple | 2 DCY |
|
||
| circuit continuity check @ warm-up mode | orbattery voltage | < 10.70 | [V] | ||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| O2S heating up phase | completed | ||||||||||
| or | |||||||||||
| O2S ceramic temperature | > 634 | [°C] | |||||||||
| Oxygen Sensor (O2S) front | P2626 - O2 Sensor Pumping Current Trim Circuit/Open Bank 1 Sensor 1 | open circuit | calculated calibration resistance | > 297.00 | [Ohm] | battery voltage | not calibrated | [V] | 5.00 [events] | 2 DCY |
|
| once / DCY | |||||||||||
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| or | |||||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| normal ASIC operation in | |||||||||||
| SWITCH ON mode | |||||||||||
| for number of events | >= 10.00 | [events] | |||||||||
| Oxygen Sensor (O2S) front | P2414 - O2 Sensor Exhaust Sample Error Bank 1 Sensor 1 | signal range check (check for sensor at ambient air) | O2S signal front | > 3.95 | [-] | engine | running | 10.0 [s] multiple | 2 DCY |
|
|
| for time | > 10.0 | [s] | O2S front | ready | |||||||
| fuel cut off | not active | ||||||||||
| PCV leakage | not detected | ||||||||||
| lambda set value | < 1.60 | [-] | |||||||||
| O2S front ceramic temperature | valid | ||||||||||
| dev. actual vs. set point O2S ceramic temperature | < 65 | [°C] | |||||||||
| only AIR system | |||||||||||
| AIR | not active | ||||||||||
| Oxygen Sensor (O2S) front | P0606 - ECM/PCM Processor | electrical check | SPI communication | error detected | battery voltage | not calibrated | [V] | 4 [events] continuous | 2 DCY |
|
|
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| Oxygen Sensor (O2S) Heater front | P0031 - HO2S Heater Control Circuit Low Bank 1 Sensor 1 | circuit low | signal voltage | <= 2.74...3.26 | [V] | duty cycle | <= 97.00 | [%] | 0.5 [s] continuous | 2 DCY |
|
| battery voltage | not calibrated | [V] | |||||||||
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| P0030 - HO2S Heater Control Circuit Bank 1 Sensor 1 | open circuit | signal voltage | > 2.74...3.26; <= 4.70...5.40 | [V] | duty cycle | <= 97.00 | [%] | 0.5 [s] | 2 DCY |
|
|
| continuous | |||||||||||
| battery voltage | not calibrated | [V] | |||||||||
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| P0032 - HO2S Heater Control Circuit High Bank 1 Sensor 1 | circuit high | signal current | >= 8.50...12.50 | [A] | duty cycle | >= 4.00 | [%] | 0.5 [s] | 2 DCY |
|
|
| continuous | |||||||||||
| battery voltage | not calibrated | [V] | |||||||||
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| Oxygen Sensor (O2S) Heater | P0135 - O2 Sensor Heater Circuit Bank 1 Sensor 1 | out of range (low temperature) | O2S ceramic temperature | < 654 | [°C] | general conditions | 2.0 [s] | 2 DCY |
|
||
| front | continuous | ||||||||||
| battery voltage | not calibrated | [V] | |||||||||
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| engine conditions | |||||||||||
| engine | running | ||||||||||
| or | |||||||||||
| modeled EGT | >= 200 | [°C] | |||||||||
| fuel cut off | not active | ||||||||||
| for time | >= 30.0 | [s] | |||||||||
| P0135 - O2 Sensor Heater Circuit Bank 1 Sensor 1 | out of range (permanent) | O2S ceramic temperature | < 680 | [°C] | general conditions | 55.0 [s] | 2 DCY |
|
|||
| continuous | |||||||||||
| battery voltage | not calibrated | [V] | |||||||||
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| effective O2S heater voltage | >= 10.70 | [V] | |||||||||
| engine conditions | |||||||||||
| engine | running | ||||||||||
| or | |||||||||||
| modeled EGT | >= 300 | [°C] | |||||||||
| fuel cut off | not active | ||||||||||
| for time | >= 40.0 | [s] | |||||||||
| P0135 - O2 Sensor Heater Circuit Bank 1 Sensor 1 | rationality check (sensor heating | O2S ceramic temperature | < 680 | [°C] | general conditions | 0 [s] | 2 DCY |
|
|||
| up after engine start) | once / DCY | ||||||||||
| battery voltage | not calibrated | [V] | |||||||||
| or | |||||||||||
| battery voltage | < 10.70 | [V] | |||||||||
| for time | < 1.5 | [s] | |||||||||
| battery voltage | > 9.80; <= 16.10 | [V] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.1 | [s] | |||||||||
| all conditions below must be | |||||||||||
| accumulated fulfilled | |||||||||||
| for time | >= 35.0 | [s] | |||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| ECT downstream engine @ start | >= -48 | [°C] | |||||||||
| for | |||||||||||
| engine | running | ||||||||||
| or | |||||||||||
| ECT downstream engine | >= -48 | [°C] | |||||||||
| for | |||||||||||
| engine | not running | ||||||||||
| conditions (improved | |||||||||||
| robustness) | |||||||||||
| battery voltage | <= 16.10 | [V] | |||||||||
| and | |||||||||||
| engine | running | ||||||||||
| and | |||||||||||
| all fuel injectors | active | ||||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for accumulated time | <= 10.0 | [s] | |||||||||
| Oxygen Sensor (O2S) rear | P013A - O2 Sensor Slow Response - Rich to Lean Bank 1 Sensor 2 | intrusive monitor | arithmetic average value | active diagnosis |
|
||||||
| check of transient time at rich to lean transition | time at rich to lean transition | not calibrated | [s] | conditions for active lambda diagnosis (referenced) | checked | 10.0 [s] once / DCY | 1 DCY | ||||
| or | passive diagnosis | ||||||||||
| EWMA filter value transient | conditions for passive lambda diagnosis during fuel cut off (referenced) | not calibrated | |||||||||
| time at rich to lean transition | > 0.6 | [s] | for arithmetic average value | ||||||||
| calculation | |||||||||||
| number of checks required for valid result | not calibrated | [-] | |||||||||
| for EWMA-filter | |||||||||||
| K-factor | 0.30 | [-] | |||||||||
| minimum number of tests per DCY required | 1 | [-] | |||||||||
| step change detection will | |||||||||||
| initiate multiple tests per DCY | |||||||||||
| conditions for step change | |||||||||||
| detection | |||||||||||
| deviation new measured value vs. old EWMA filtered value | > 0.4 | [s] | |||||||||
| number of checks for confirmation | 3.00 | [-] | |||||||||
| maximum tolerance to confirm filtered value | 0.20 | [s] | |||||||||
| initial value of filtered value | 0.0 | [s] | |||||||||
| maximum number of checks per DCY | 3.00 | [-] | |||||||||
| additional conditions | |||||||||||
| no additional conditions calibrated | |||||||||||
| Oxygen Sensor (O2S) rear | P013B - O2 Sensor Slow Response - Lean to Rich Bank 1 Sensor 2 | intrusive monitor | arithmetic average value | monitor entry conditions |
|
||||||
| check of transient time at lean to rich transition | time at lean to rich transition | not calibrated | [s] | conditions for active lambda diagnosis (referenced) | checked | 10.0 [s] once / DCY | 1 DCY | ||||
| or | for arithmetic average value | ||||||||||
| calculation | |||||||||||
| EWMA filter value transient | number of checks required for valid result | not calibrated | [-] | ||||||||
| time at lean to rich transition | > 1.5 | [s] | for EWMA-filter: | ||||||||
| K-factor | 0.30 | [-] | |||||||||
| minimum number of tests per DCY required | 1 | ||||||||||
| step change detection will | |||||||||||
| initiate multiple tests per DCY | |||||||||||
| conditions for step change | |||||||||||
| detection | |||||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| deviation between new | > 0.8 | [s] | |||||||||
| measured value and old EWMA | |||||||||||
| filtered value | |||||||||||
| number of checks for | 3.00 | [-] | |||||||||
| confirmation | |||||||||||
| maximum tolerance to confirm | 0.40 | [s] | |||||||||
| filtered value | |||||||||||
| initial value of filtered value | 0.0 | [s] | |||||||||
| maximum number of checks per | 3.00 | [-] | |||||||||
| driving cycle | |||||||||||
| additional conditions | |||||||||||
| no additional conditions | |||||||||||
| calibrated | |||||||||||
| Oxygen Sensor (O2S) rear | P013E - O2 Sensor Delayed Response - Rich to Lean Bank 1 Sensor 2 | intrusive monitor | arithmetic average value | monitor entry conditions |
|
||||||
| delayed response monitoring, delay measurement | delay time at rich to lean transition | not calibrated | [s] | conditions for active lambda diagnosis (referenced) | checked | 20.0 [s] once / DCY | 1 DCY | ||||
| or | for arithmetic average value | ||||||||||
| calculation | |||||||||||
| EWMA filter value transient | number of checks required for valid result | not calibrated | [-] | ||||||||
| delay time at rich to lean transition | > 0.3 | [s] | for EWMA-filter: K-factor | 0.30 | [-] | ||||||
| minimum number of tests per DCY required | 1 | ||||||||||
| step change detection will | |||||||||||
| initiate multiple tests per DCY | |||||||||||
| conditions for step change | |||||||||||
| detection | |||||||||||
| deviation between new measured value and old EWMA filtered value | > 0.4 | [s] | |||||||||
| number of checks for confirmation | 5.00 | [-] | |||||||||
| maximum tolerance to confirm filtered value | 0.20 | [s] | |||||||||
| initial value of filtered value | 0.0 | [s] | |||||||||
| maximum number of checks per driving cycle | 3.00 | [-] | |||||||||
| additional conditions | |||||||||||
| no additional conditions calibrated | |||||||||||
| Oxygen Sensor (O2S) rear | Pouf - O2 Sensor Delayed Response - Lean to Rich Bank 1 Sensor 2 | intrusive monitor | arithmetic average value | monitor entry conditions |
|
||||||
| delayed response monitoring, delay measurement | delay time at lean to rich transition | not calibrated | [s] | conditions for active lambda diagnosis (referenced) | checked | 20.0 [s] once / DCY | 1 DCY | ||||
| or | for arithmetic average value | ||||||||||
| calculation | |||||||||||
| EWMA filter value transient | number of checks required for valid result | not calibrated | [-] | ||||||||
| delay time at lean to rich transition | > 0.6 | [s] | for EWMA-filter: K-factor | 0.30 | [-] | ||||||
| minimum number of tests per DCY required | 1 | ||||||||||
| step change detection will | |||||||||||
| initiate multiple tests per DCY | |||||||||||
| conditions for step change | |||||||||||
| detection | |||||||||||
| deviation between new measured value and old EWMA filtered value | > 0.4 | [s] | |||||||||
| number of checks for confirmation | 5.00 | [-] | |||||||||
| maximum tolerance to confirm filtered value | <= 0.20 | [s] | |||||||||
| initial value of filtered value | 0.0 | [s] | |||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| maximum number of checks per driving cycle additional conditions no additional conditions calibrated | 3.00 | [-] | |||||||||
| Oxygen Sensor (O2S) rear | P2271 - O2 Sensor Signal Biased/Stuck Rich Bank 1 Sensor 2 | intrusive monitor | general | active diagnosis (general) | |||||||
| O2S signal check - stuck high | O2S sensor voltage | > 0.15 | [V] | conditions for active lambda diagnosis (referenced) | checked | 20.0 [s] once / DCY | 2 DCY |
|
|||
| and | active diagnosis (step 1) | ||||||||||
| active diagnosis (step 1) | requested lambda | 1.06...1.08 | [-] | ||||||||
| cumulated O2 mass flow into catalyst | >= 1500 | [mg] | active diagnosis (step 2) | ||||||||
| and | requested lambda | not calibrated | [-] | ||||||||
| active diagnosis (step 2) | or | ||||||||||
| integrated exhaust gas mass flow | not calibrated | [g] | passive diagnosis | ||||||||
| for time | not calibrated | [s] | conditions for passive lambda diagnosis during fuel cut off (referenced) | not calibrated | |||||||
| or | additional conditions: | ||||||||||
| passive diagnosis cumulated O2 mass flow into catalyst | not calibrated | [mg] | no additional conditions calibrated | ||||||||
| Oxygen Sensor (O2S) rear | P2270 - O2 Sensor Signal Biased/Stuck Lean Bank 1 Sensor 2 | intrusive monitor | general | general conditions |
|
||||||
| O2S signal check - stuck low | O2S sensor voltage | < 0.75 | [V] | conditions for active lambda diagnosis (referenced) | checked | 20.0 [s] once / DCY | 2 DCY | ||||
| and | step 1 | ||||||||||
| step 1 | requested lambda | 0.90 | [-] | ||||||||
| cumulated rich gas mass flow into catalyst | >= 1500 | [mg] | step 2 | ||||||||
| and | requested lambda | not calibrated | [-] | ||||||||
| step 2 | additional conditions: | ||||||||||
| integrated exhaust gas mass flow | not calibrated | [g] | no additional conditions calibrated | ||||||||
| for time | not calibrated | [s] | |||||||||
| Oxygen Sensor (O2S) rear | P0137 - O2 Sensor Circuit Low Voltage Bank 1 Sensor 2 | O2S signal check - circuit continuity (circuit low) | difference of sensor voltage with load pulse and voltage without load pulse (mean value of 3 measurements) | < 0.01 | [V] | general conditions engine running ECM drive mode | not calibrated detected | 3.0 [s] multiple | 2 DCY |
|
|
| injection cut off | not active | ||||||||||
| fuel cut off | not calibrated | ||||||||||
| catalyst purge | not active | ||||||||||
| battery voltage | > 10.70 | [V] | |||||||||
| all conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 3.0 | [s] | |||||||||
| conditions for fault suspicion | |||||||||||
| O2S rear signal voltage | < 0.03 | [V] | |||||||||
| for time | >= 3.0 | [s] | |||||||||
| number of loaded measurements | 3 | [-] | |||||||||
| time delay between two load pulses (for confirming suspicion) | 5.0 | [s] | |||||||||
| P0138 - O2 Sensor Circuit High Voltage Bank 1 Sensor 2 | O2S signal check - circuit continuity (circuit high) | signal voltage | > 1.26 | [V] | general conditions | 0.2 [s] multiple | 2 DCY |
|
|||
| within | cold sensor operation | not calibrated | |||||||||
| lambda value | > 0.995 | [-] | normal range operation | detected | |||||||
| or | engine running | not calibrated | |||||||||
| signal voltage @ cold sensor operation | not calibrated | [V] | ECM drive mode battery voltage | detected > 10.70 | [V] | ||||||
| internal resistance check | successful | ||||||||||
| within | |||||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| number of successful resistance | > 10.00 | [-] | |||||||||
| measurements | |||||||||||
| and | |||||||||||
| time between two successful | <= 8 | [s] | |||||||||
| resistance measurements | |||||||||||
| alternative conditions | |||||||||||
| (diagnostics readiness is set | |||||||||||
| independently of the sensor | |||||||||||
| operating readiness) | |||||||||||
| time after protection heating | not calibrated | [s] | |||||||||
| mode finished | |||||||||||
| additional time delay | not calibrated | [s] | |||||||||
| O2S is sufficiently electrically | not calibrated | ||||||||||
| heated | |||||||||||
| within | |||||||||||
| time delay | not calibrated | [s] | |||||||||
| conditions below must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.2 | [s] | |||||||||
| internal resistance | <= 700.00 | [Ohm] | |||||||||
| number of resistance | >= 3.00 | [-] | |||||||||
| measurements | |||||||||||
| or | |||||||||||
| O2S rear protective heating | finished | ||||||||||
| within | |||||||||||
| time delay | >= 15.0 | [s] | |||||||||
| normalized heating power | >= 0.25 | [-] | |||||||||
| or | |||||||||||
| EGT @ O2S rear | >= 550 | [°C] | |||||||||
| for time | >= 25.5 | [s] | |||||||||
| internal sensor resistance is | detected | ||||||||||
| sufficiently low | |||||||||||
| within | |||||||||||
| sensor voltage @ rich conditions | 0.55...1.26 | [V] | |||||||||
| or | |||||||||||
| sensor voltage @ lean | <= 0.32 | [V] | |||||||||
| conditions | |||||||||||
| Oxygen Sensor (O2S) rear | P0140 - O2 Sensor Circuit No Activity Detected Bank 1 Sensor 2 | O2S signal check - circuit continuity (open circuit) | sensor signal line difference of sensor voltage with load pulse and voltage without load pulse (mean value of 3 measurements) | >= 2.80 | [V] | ECM drive mode normal range conditions | detected | 0 [s] multiple | 2 DCY |
|
|
| sensor ground line | battery voltage | > 10.70 | [V] | ||||||||
| internal resistance | not calibrated | [Ohm] | engine running | not calibrated | |||||||
| and | internal resistance check | successful | |||||||||
| EGT | not calibrated | [°C] | within | ||||||||
| number of successful resistance measurements | > 10.00 | [-] | |||||||||
| and | |||||||||||
| time between two successful resistance measurements | 8 | [s] | |||||||||
| alternative conditions | |||||||||||
| (diagnostics readiness is set | |||||||||||
| independently of the sensor | |||||||||||
| operating readiness) | |||||||||||
| time after protection heating mode finished | not calibrated | [s] | |||||||||
| additional time delay | not calibrated | [s] | |||||||||
| O2S is sufficiently electrically heated | not calibrated | ||||||||||
| within | |||||||||||
| time delay | not calibrated | [s] | |||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| conditions below must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 0.2 | [s] | |||||||||
| internal resistance | <= 700.00 | [Ohm] | |||||||||
| number of resistance | >= 3.00 | [-] | |||||||||
| measurements | |||||||||||
| or | |||||||||||
| O2S rear protective heating | finished | ||||||||||
| within | |||||||||||
| time delay | >= 15.0 | [s] | |||||||||
| normalized heating power | >= 0.25 | [-] | |||||||||
| or | |||||||||||
| EGT @ O2S rear | >= 550 | [°C] | |||||||||
| for time | >= 25.5 | [s] | |||||||||
| internal sensor resistance is | detected | ||||||||||
| sufficiently low | |||||||||||
| within | |||||||||||
| sensor voltage @ rich conditions | 0.55...1.26 | [V] | |||||||||
| or | |||||||||||
| sensor voltage @ lean | <= 0.32 | [V] | |||||||||
| conditions | |||||||||||
| conditions for fault suspicion | |||||||||||
| (only for "sensor signal line") | |||||||||||
| O2S rear signal voltage | 0.32...0.55 | [V] | |||||||||
| for time | >= 3.0 | [s] | |||||||||
| number of loaded | 3 | [-] | |||||||||
| measurements | |||||||||||
| time delay between two load | 5.0 | [s] | |||||||||
| pulses (for confirming suspicion) | |||||||||||
| Oxygen Sensor (O2S) Heater rear | P0037 - HO2S Heater Control Circuit Low Bank 1 Sensor 2 | circuit low | signal voltage | <= 2.74...3.26 | [V] | general conditions | 0.5 [s] | 2 DCY |
|
||
| continuous | |||||||||||
| engine speed | >= 0 | [RPM] | |||||||||
| battery voltage | > 8.90 | [V] | |||||||||
| battery voltage | not calibrated | [V] | |||||||||
| duty cycle | <= 98 | [%] | |||||||||
| conditions for dew point end | |||||||||||
| battery voltage | <= 16.50 | [V] | |||||||||
| ECM post drive | not detected | ||||||||||
| heating @ ECM pre-drive | not calibrated | ||||||||||
| or | |||||||||||
| engine | running | ||||||||||
| or | |||||||||||
| drive motor | not equipped | ||||||||||
| protection heating | active | ||||||||||
| heating @ stop phase | |||||||||||
| wall temperature | > -40 | [°C] | |||||||||
| or | |||||||||||
| EGT | > -40 | [°C] | |||||||||
| all above conditions (except | |||||||||||
| general conditions) must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 10.0 | [s] | |||||||||
| fast enable conditions (for | |||||||||||
| sufficient battery voltage or | |||||||||||
| AAT) | |||||||||||
| battery voltage | < 15.00 | [V] | |||||||||
| or | |||||||||||
| AAT | not calibrated | [°C] | |||||||||
| for time | >= 5.0 | [s] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 15.0 | [s] | |||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| P0036 - HO2S Heater Control Circuit Bank 1 Sensor 2 | open circuit | signal voltage | > 2.74...3.26; <= 4.70...5.40 | [V] | general conditions | 0.5 [s] | 2 DCY |
|
|||
| continuous | |||||||||||
| engine speed | >= 0 | [RPM] | |||||||||
| battery voltage | > 8.90 | [V] | |||||||||
| battery voltage | not calibrated | [V] | |||||||||
| duty cycle | <= 98 | [%] | |||||||||
| conditions for dew point end | |||||||||||
| battery voltage | <= 16.50 | [V] | |||||||||
| ECM post drive | not detected | ||||||||||
| heating @ ECM pre drive | not calibrated | ||||||||||
| or | |||||||||||
| engine | running | ||||||||||
| or | |||||||||||
| drive motor | not equipped | ||||||||||
| protection heating | active | ||||||||||
| heating @ stop phase | |||||||||||
| wall temperature | > -40 | [°C] | |||||||||
| or | |||||||||||
| EGT | > -40 | [°C] | |||||||||
| all above conditions (except | |||||||||||
| general conditions) must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 10.0 | [s] | |||||||||
| fast enable conditions (for | |||||||||||
| sufficient battery voltage or | |||||||||||
| AAT) | |||||||||||
| battery voltage | < 15.00 | [V] | |||||||||
| or | |||||||||||
| AAT | not calibrated | [°C] | |||||||||
| for time | >= 5.0 | [s] | |||||||||
| conditions above must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 15.0 | [s] | |||||||||
| P0038 - HO2S Heater Control Circuit High Bank 1 Sensor 2 | circuit high | signal current | >= 8.5...12.5 | [A] | general conditions | 0.5 [s] | 2 DCY |
|
|||
| continuous | |||||||||||
| engine speed | >= 0 | [RPM] | |||||||||
| battery voltage | > 8.90 | [V] | |||||||||
| battery voltage | not calibrated | [V] | |||||||||
| duty cycle | >= 3 | [%] | |||||||||
| conditions for dew point end | |||||||||||
| battery voltage | <= 16.50 | [V] | |||||||||
| ECM post drive | not detected | ||||||||||
| heating @ ECM pre drive | not calibrated | ||||||||||
| or | |||||||||||
| engine | running | ||||||||||
| or | |||||||||||
| drive motor | not equipped | ||||||||||
| protection heating | active | ||||||||||
| heating @ stop phase | |||||||||||
| wall temperature | > -40 | [°C] | |||||||||
| or | |||||||||||
| EGT | > -40 | [°C] | |||||||||
| all above conditions (except | |||||||||||
| general conditions) must be | |||||||||||
| fulfilled | |||||||||||
| for time | >= 10.0 | [s] | |||||||||
| fast enable conditions (for | |||||||||||
| sufficient battery voltage or | |||||||||||
| AAT) | |||||||||||
| battery voltage | < 15.00 | [V] | |||||||||
| or | |||||||||||
| AAT | not calibrated | [°C] | |||||||||
| for time | >= 5.0 | [s] | |||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| conditions above must be fulfilled for time | >= 15.0 | [s] | |||||||||
| Oxygen Sensor (O2S) Heater rear | P0141 - O2 Sensor Heater Circuit Bank 1 Sensor 2 | out of range (during normal | internal resistance | > 1800.00...131070.00 | [Ohm] | general conditions: | 126.0 [s] | 2 DCY |
|
||
| heater operation after Dew Point | multiple | ||||||||||
| is exceeded) | |||||||||||
| O2S heated up for time | >= 45.0 | [s] | |||||||||
| modeled EGT | 250...650 | [°C] | |||||||||
| modeled EGT | valid | ||||||||||
| IAT downstream CAC | > -48 | [°C] | |||||||||
| engine off time | > 300.0 | [s] | |||||||||
| counter for engine off time | valid | ||||||||||
| engine | running | ||||||||||
| battery voltage | 10.70...16.10 | [V] | |||||||||
| number of valid internal | > 10.00 | [-] | |||||||||
| resistance checks | |||||||||||
| fuel cut off | not active | ||||||||||
| O2S heater | commanded on | ||||||||||
| conditions after long stop | |||||||||||
| phase: | |||||||||||
| time after engine stop | >= 120.0 | [s] | |||||||||
| time after next engine start | >= 30.0 | [s] | |||||||||
| Positive Crankcase Ventilation (PCV) | P04DB - Crankcase Ventilation System Disconnected | functional monitoring: disconnected PCV hose upstream TC | electrical check | error detected | 1.1 [s] continuous | 2 DCY |
|
||||
| P04DB - Crankcase Ventilation System Disconnected | functional monitoring: disconnected PCV hose non-return valve | electrical check | error detected | 1.1 [s] continuous | 2 DCY |
|
|||||
| Engine Cooling System | P2181 - Cooling System Performance | cooling system performance not | cooling system temperature too | < 55...63 | [°C] | monitor entry conditions: | 0 (Unified 540.0) [s] | 2 DCY |
|
||
| in the expected range | low after a sufficient MAF | once / DCY | |||||||||
| integral | |||||||||||
| for time | >= 10.0 | [s] | ECT downstream engine @ start | -10...44 | [°C] | ||||||
| and | |||||||||||
| AAT | -10...45 | [°C] | |||||||||
| or | |||||||||||
| IAT downstream CAC | not calibrated | [°C] | |||||||||
| begin of air mass integration: | |||||||||||
| ECT downstream engine | > 10 | [°C] | |||||||||
| conditions for diagnosis: | |||||||||||
| MAF | < 3276.70 | [kg/h] | |||||||||
| delta BARO | < 100.00 | [kPa] | |||||||||
| delta AAT | < 190.5 | [K] | |||||||||
| and | |||||||||||
| accum. time required | not calibrated | [s] | |||||||||
| or | |||||||||||
| accum. integrated air mass | < 0.25...1.20 | [kg] | |||||||||
| accumulation enable if | |||||||||||
| fuel cut off | active | ||||||||||
| or | |||||||||||
| engine load | > 250.00 | [%] | |||||||||
| or | |||||||||||
| engine load | < 18.01...45.00 | [%] | |||||||||
| start of fault decision: | |||||||||||
| integrated air mass | > 2.80...9.00 | [kg] | |||||||||
| conditions at fault decision: | |||||||||||
| (average values since start) | |||||||||||
| MAF (lower threshold) | >= 28.80...86.00 | [kg/h] | |||||||||
| MAF (upper threshold) | <= 57.70...189.50 | [kg/h] | |||||||||
| vehicle speed (lower threshold) | >= 20...30 | [km/h] | |||||||||
| vehicle speed (upper threshold) | <= 120 | [km/h] | |||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Engine Cooling System | P2181 - Cooling System Performance | cooling system performance not | filtered ECT downstream engine | < 55 | [°C] | general | 0 (Unified 520.0) [s] | 2 DCY |
|
||
| in the expected range | once / DCY | ||||||||||
| for time | >= 10.0 | [s] | AAT | > -10 | [°C] | ||||||
| air mass flow integral | > 1.5...4.5 | [g] | |||||||||
| or | |||||||||||
| modeled ECT | not calibrated | [°C] | |||||||||
| for | |||||||||||
| ECT once after engine start | > 55...63 | [°C] | |||||||||
| valid operating points | |||||||||||
| engine | running | ||||||||||
| for time | > 20.0 | [s] | |||||||||
| fuel cut off | not active | ||||||||||
| for time | > 380.0 | [s] | |||||||||
| modeled ECT | not calibrated | [°C] | |||||||||
| thermostat overdrive | not detected | ||||||||||
| for time | > 20.0 | [s] | |||||||||
| vehicle speed | > 20 | [km/h] | |||||||||
| and | |||||||||||
| vehicle speed | < 328 | [km/h] | |||||||||
| for time | > 20.0 | [s] | |||||||||
| engine load | > 29.99...55.00 | [%] | |||||||||
| and | |||||||||||
| engine load | < 399.99 | [%] | |||||||||
| for time | > 380.0 | [s] | |||||||||
| additional conditions for re- | |||||||||||
| entry after strong ECT drop | |||||||||||
| integrated air mass flow during | > 700.0...4850.0 | [g] | |||||||||
| valid operating points | |||||||||||
| depending on | |||||||||||
| min. AAT @ current DCY | -10...45 | [°C] | |||||||||
| ECT @ entry of valid operating | 20...50 | [°C] | |||||||||
| points | |||||||||||
| all conditions above (except | |||||||||||
| general) must be fulfilled | |||||||||||
| for time | > 10.0 | [s] | |||||||||
| Engine Cooling System | P0125 - Insufficient Coolant Temperature for Closed Loop Fuel Control | engine coolant temperature too low after a sufficient time | ECT | < 15 | [°C] | general | 0 [s] once / DCY | 2 DCY |
|
||
| depending on | timer value since first engine start | >= 120.0...600.0 | [s] | ||||||||
| ECT @ start | -40...40 | [°C] | depending on | ||||||||
| diff. ECT for closed loop enable vs. actual ECT | 0.0...35.0 | [K] | |||||||||
| conditions for timer start / | |||||||||||
| increment | |||||||||||
| engine | running | ||||||||||
| conditions for timer freeze | |||||||||||
| fuel cut off | not calibrated | ||||||||||
| or | |||||||||||
| fuel volume flow | <= 0.54 | [l/h] | |||||||||
| above conditions must be | |||||||||||
| fulfilled | |||||||||||
| for time | <= 0.0 | [s] | |||||||||
| conditions for timer | |||||||||||
| decrement | |||||||||||
| fuel cut off | active | ||||||||||
| or | |||||||||||
| fuel volume flow | <= 0.00 | [l/h] | |||||||||
| above conditions must be | |||||||||||
| fulfilled | |||||||||||
| for time | > 8.0...20.0 | [s] | |||||||||
| depending on | |||||||||||
| AAT | -40...40 | [°C] | |||||||||
| timer set value | 0.0...300.0 | [s] | |||||||||
| conditions for timer reset | |||||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| fuel cut off or fuel volume flow above conditions must be fulfilled for time depending on AAT or for accumulated time depending on AAT timer set value | not calibrated not calibrated not calibrated not calibrated not calibrated not calibrated not calibrated | [l/h] [s] [°C] [s] [°C] [s] | |||||||||
| Supplementary Coolant Pump | P261A - Coolant Pump "B" Control Circuit/Open | open circuit | signal voltage | > 2.74...3.26; <= 4.70...5.40 | [V] | actuator | commanded off | 0.5 [s] | 2 DCY |
|
|
| continuous | |||||||||||
| battery voltage | >= -655.36 | [V] | |||||||||
| for time | >= 0 | [ms] | |||||||||
| Supplementary Coolant Pump | P261D - Coolant Pump "B" Control Circuit High | circuit high | signal current | >= 2.20...4.00 | [A] | actuator | commanded on | 0.5 [s] | 2 DCY |
|
|
| continuous | |||||||||||
| battery voltage | >= -655.36 | [V] | |||||||||
| for time | >= 0 | [ms] | |||||||||
| Supplementary Coolant Pump | P0634 - Control Module Internal Temperature "A" Too High | over-temperature power stage | power stage temperature | >= 155...165 | [°C] | actuator | commanded on | 0.5 [s] | 2 DCY |
|
|
| continuous | |||||||||||
| battery voltage | >= -655.36 | [V] | |||||||||
| for time | >= 0 | [ms] | |||||||||
| - if equipped -Active Grille Air Shutter | P05A3 - Active Grille Air Shutter "A" Control Circuit Range/Performance | functional check | actuator | no feedback | actuator | commanded on | 150.0 [s] continuous | 2 DCY |
|
||
| Engine Oil Pressure (EOP) Control Actuator | P06DB - Engine Oil Pressure Control Circuit Low | circuit low | signal voltage | <= 2.74...3.26 | [V] | actuator battery voltage | commanded off 8.80...16.20 | [V] | 200.00 [ms] continuous | 2 DCY |
|
| P06DA - Engine Oil Pressure Control Circuit/Open | open circuit | signal voltage | > 2.74...3.26; <= 4.70...5.40 | [V] | actuator battery voltage | commanded off 8.80...16.20 | [V] | 200.00 [ms] continuous | 2 DCY |
|
|
| P06DC - Engine Oil Pressure Control Circuit High | circuit high | signal current | >= 2.20...4.00 | [A] | actuator battery voltage | commanded on 8.80...16.20 | [V] | 200.00 [ms] continuous | 2 DCY |
|
|
| Engine Oil Pressure (EOP) Control Actuator | P0634 - Control Module Internal Temperature "A" Too High | over-temperature power stage | power stage temperature | >= 155...165 | [°C] | actuator battery voltage | commanded on 8.80...16.20 | [V] | 200.00 [ms] continuous | 2 DCY |
|
| Engine Oil Pressure (EOP) HP Switch | P055C - Engine Oil Pressure Sensor/Switch "B" Low | rationality check | EOP (HP) switch signal | permanently high | ECM after run | active | 60.0 [s] once / DCY | 2 DCY |
|
||
| for time | > 61.5 | [s] | |||||||||
| EOT | > 10 | [°C] | |||||||||
| battery voltage | 9.00...16.50 | [V] | |||||||||
| Engine Oil Pressure (EOP) HP Switch | P055F - Engine Oil Pressure Out of Range | rationality check | engine speed | > 3000...4000 | [RPM] | engine | running | 10.0 [s] continuous | 2 DCY |
|
|
| and | for time | > 5.0...45.0 | [s] | ||||||||
| engine oil pump @ high pressure | not detected | battery voltage | 9.00...16.50 | [V] | |||||||
| and | |||||||||||
| EOP (HP) switch signal | permanently low | ||||||||||
| Engine Oil Pressure (EOP) LP Switch | P0522 - Engine Oil Pressure Sensor/Switch "A" Low | rationality check | EOP (LP) switch signal | permanently high | ECM after run | active | 60.0 [s] once / DCY | 2 DCY |
|
||
| for time | > 61.5 | [s] | |||||||||
| EOT | > 10 | [°C] | |||||||||
| battery voltage | 9.00...16.50 | [V] | |||||||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Engine Oil Pressure (EOP) LP Switch | P0524 - Engine Oil Pressure Too Low | rationality check | engine speed and EOP (LP) switch signal | > 650...1500 permanently low | [RPM] | engine for time battery voltage | running > 5.0...45.09.00...16.50 | [s] [V] | 8.0 [s] continuous | 2 DCY |
|
| Engine Coolant Temperature | P0116 - Engine Coolant Temperature Sensor 1 Circuit Range/Performance | stuck high / low - no change on | diff. between max. ECT | < 1.5 | [K] | ECT downstream engine @ start | -40...141 | [°C] | 142.0 [s] | 2 DCY |
|
| (ECT) Sensor downstream | signal | downstream engine and min. | once / DCY | ||||||||
| engine | ECT downstream engine | substitute ECT | > -45 | [°C] | |||||||
| driving condition H: | |||||||||||
| vehicle speed | 0...180 | [km/h] | |||||||||
| MAF (lower threshold) | 0.00 | [kg/h] | |||||||||
| MAF (upper threshold) | 48.00 | [kg/h] | |||||||||
| or | |||||||||||
| fuel cut off | active | ||||||||||
| for | |||||||||||
| time required | > 30.0 | [s] | |||||||||
| frequency | 3 | times | |||||||||
| driving condition L: | |||||||||||
| vehicle speed | 0...180 | [km/h] | |||||||||
| MAF (lower threshold) | 4.00 | [kg/h] | |||||||||
| MAF (upper threshold) | 152.00...300.00 | [kg/h] | |||||||||
| for | |||||||||||
| time required | > 25.0 | [s] | |||||||||
| frequency | 2 | times | |||||||||
| P0116 - Engine Coolant Temperature Sensor 1 Circuit Range/Performance | stuck in range | ECT downstream engine @ start | >= 80 | [°C] | engine off time | > 21600.0 | [s] | 2.0 [s] | 2 DCY |
|
|
| once / DCY | |||||||||||
| and | |||||||||||
| ECT downstream engine @ start | <= 143 | [°C] | |||||||||
| Engine Coolant Temperature (ECT) Sensor down stream engine | P0117 - Engine Coolant Temperature Sensor 1 Circuit Low | circuit low | ECT downstream engine | > 135 | [°C] | 2.0 [s] continuous | 2 DCY |
|
|||
| Engine Coolant Temperature (ECT) Sensor downstream engine | P0118 - Engine Coolant Temperature Sensor 1 Circuit High | circuit high | ECT downstream engine | < -45 | [°C] | 2.0 [s] continuous | 2 DCY |
|
|||
| Engine Coolant Temperature (ECT) Sensor down stream engine | P0116 - Engine Coolant Temperature Sensor 1 Circuit Range/Performance | rationality check | diff. modeled vs. measured ECT downstream engine | > 10.5 | [K] | 47.5 [s] continuous | 2 DCY |
|
|||
| Engine Coolant Temperature | P0116 - Engine Coolant Temperature Sensor 1 Circuit Range/Performance | rationality check high | ECT downstream engine @ start | > 56...80 | [°C] | engine off time | > 21600.0 | [s] | 3.0 [s] | 2 DCY |
|
| (ECT) Sensor downstream | once / DCY | ||||||||||
| engine | engine | running | |||||||||
| for time | >= 3.0 | [s] | |||||||||
| Engine Coolant Temperature (ECT) Sensor down stream engine | P0116 - Engine Coolant Temperature Sensor 1 Circuit Range/Performance | rationality check low | ECT downstream engine @ start vs. minimum temperature from cross check | < -20.0 | [K] | cross check (temperature) | finished | 0 [s] once / DCY | 2 DCY |
|
|
| Engine Coolant Temperature (ECT) Sensor @ Radiator Outlet | P2184 - Engine Coolant Temperature Sensor 2 Circuit Low | circuit low | signal voltage | < 0.25 | [V] | 0.50 [s] continuous | 2 DCY |
|
|||
| P2185 - Engine Coolant Temperature Sensor 2 Circuit High | circuit high | signal voltage | > 4.87 | [V] | 0.50 [s] continuous | 2 DCY |
|
||||
| Variable Valve Timing (VVT) Intake Actuator | P000A - "A" Camshaft Position Slow Response Bank 1 | slow response | difference between target position vs. actual position for time and adjustment angle and number of checks | > | 3.00 |> 2.0...3.0> | 3.00 |3 | [°CRK] [s] [°CRK] times | time after engine start engine speed modeled oil temperature change of target position | > 5.0...10.0800...6400-10...110> |10.00| | [s] [RPM] [°C] [°CRK] | 3.0 [s] multiple | 2 DCY |
|
| P0011 - "A" Camshaft Position - Timing Over-Advanced or System Performance Bank 1 | target error | difference between target position vs. actual position for time and | > | 3.00 |> 2.0...3.0 | [°CRK][s] | time after engine start engine speed modeled oil temperature | > 5.0...10.0800...6400-10...110 | [s] [RPM] [°C] | 3.0 [s] multiple | 2 DCY |
|
|
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| adjustment angle and number of checks | <= | 3.00 |3 | [°CRK] times | change of target position | > |10.00| | [°CRK] | ||||||
| Variable Valve Timing (VVT) Intake Actuator | P2088 - "A" Camshaft Position Actuator Control Circuit Low Bank 1 | circuit low | signal voltage | <= 2.74...3.26 | [V] | duty cycle engine speed battery voltage | >= 6.25; <= 90>= 0> 8.9 | [%] [RPM] [V] | 0.5 [s] continuous | 2 DCY |
|
| P0010 - "A" Camshaft Position Actuator "A" Control Circuit/Open Bank 1 | open circuit | signal voltage | > 2.74...3.26; <=4.70...5.40 | [V] | duty cycle engine speed battery voltage | >= 6.25; <= 90>= 0> 8.9 | [%] [RPM] [V] | 0.5 [s] continuous | 2 DCY |
|
|
| P2089 - "A" Camshaft Position Actuator Control Circuit High Bank 1 | circuit high | signal current | >= 3.00...6.00 | [A] | duty cycle engine speed battery voltage | >= 6.25; <= 90>= 0> 8.9 | [%] [RPM] [V] | 0.5 [s] continuous | 2 DCY |
|
|
| Cold Start Monitoring Variable Valve Timing (VVT) Intake Actuator | P052A - Cold Start "A" Camshaft Position Timing Over-Advanced Bank 1 | target error | difference between target position vs. actual position | > |10.00...40.00| | [°CRK] | time after engine start engine speed modeled oil temperature commanded camshaft timing correction for catalyst heating | >= 3.0...500.0 >= 600...1120 -35...145 active | [s] [RPM] [°C] | 3.0 [s] once / DCY | 2 DCY |
|
| Cold Start Monitoring Variable Valve Timing (VVT) Exhaust Actuator | P054A - Cold Start "B" Camshaft Position Timing Over-Advanced Bank 1 | target error | difference between target position vs. actual position | > |10.00...22.00| | [°CRK] | time after engine start engine speed modeled oil temperature commanded camshaft timing correction for catalyst heating | >= 3.0...500.0>= 600...1120-35...145 active | [s] [RPM] [°C] | 3.0 [s] once / DCY | 2 DCY |
|
| Variable Valve Timing (VVT) Exhaust Actuator | P000B - "B" Camshaft Position Slow Response Bank 1 | slow response | difference between target position vs. actual position for time and adjustment angle and number of checks | > | 3.00 |> 2.0...3.0> | 3.00 |3 | [°CRK] [s] [°CRK] times | time after engine start engine speed modeled oil temperature change of target position | > 5.0...10.0800...6400-10...110> |10.00| | [s] [RPM] [°C] [°CRK] | 3.0 [s] multiple | 2 DCY |
|
| P0014 - "B" Camshaft Position - Timing Over-Advanced or System Performance Bank 1 | target error | difference between target position vs. actual position for time and adjustment angle and number of checks | > | 3.00 |> 2.0...3.0<= | 3.00 |3 | [°CRK] [s] [°CRK] times | time after engine start engine speed modeled oil temperature change of target position | > 5.0...10.0800...6400-10...110> |10.00| | [s] [RPM] [°C] [°CRK] | 3.0 [s] multiple | 2 DCY |
|
|
| Variable Valve Timing (VVT) Exhaust Actuator | P2090 - "B" Camshaft Position Actuator Control Circuit Low Bank 1 | circuit low | signal voltage | <= 2.74...3.26 | [V] | duty cycle engine speed battery voltage | >= 6.25; <= 90>= 0> 8.9 | [%] [RPM] [V] | 0.5 [s] continuous | 2 DCY |
|
| P0013 - "B" Camshaft Position Actuator "A" Control Circuit/Open Bank 1 | open circuit | signal voltage | > 2.74...3.26; <= 4.70...5.40 | [V] | duty cycle engine speed battery voltage | >= 6.25; <= 90>= 0> 8.9 | [%] [RPM] [V] | 0.5 [s] continuous | 2 DCY |
|
|
| P2091 - "B" Camshaft Position Actuator Control Circuit High Bank 1 | circuit high | signal current | >= 3.00...6.00 | [A] | duty cycle engine speed battery voltage | >= 6.25; <= 90>= 0> 8.9 | [%] [RPM] [V] | 0.5 [s] continuous | 2 DCY |
|
|
| Intake Camshaft Position (CMP) Sensor | P0343 - Camshaft Position Sensor "A" Circuit High Bank 1 or Single Sensor | circuit high | signal voltage and crankshaft signal counter | permanently high>= 8 | [-] | 0.5 [s] continuous | 2 DCY |
|
|||
| P0342 - Camshaft Position Sensor "A" Circuit Low Bank 1 or Single Sensor | circuit low | signal voltage and crankshaft signal counter | permanently low>= 8 | [-] | 0.5 [s] continuous | 2 DCY |
|
||||
Table continues below.
| Component / System | Fault Code | Monitor Strategy Description | Malfunction Criteria | Threshold Value | Secondary Parameters | Enable Condition | Monitoring Time Length | MIL Illum | Component Diagnostic | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| P0341 - Camshaft Position Sensor "A" Circuit Range/Performance Bank 1 or Single Sensor | rationality check | signal pattern defect counter | incorrect 24 | [-] | 0.5 [s] continuous | 2 DCY |
|
||||
| Intake Camshaft Position (CMP) Sensor | P0016 - Crankshaft Position - Camshaft Position Correlation Bank 1 Sensor A | angular offset check | permissible deviation or permissible deviation | < -15.01> 15.01 | [°CRK] [°CRK] | camshaft adaptation engine speed | not completed > 80 | [RPM] | 8 [rev] multiple | 2 DCY |
|
| Intake Camshaft Position (CMP) Sensor | P0016 - Crankshaft Position - Camshaft Position Correlation Bank 1 Sensor A | rationality check (only once after EEPROM reset) | difference between target position vs. actual position for camshaft signals or difference between target position vs. actual position for camshaft signals | > 10.00> 4.00< 10.00> 4.00 | [°CRK] [-] [°CRK] [-] | engine speed condition for empty EEPROM camshaft adaptation @ 1st start in lifetime | > 80 not finished | [RPM] | 1.0 [s] / once per lifetime | 1 DCY |
|
| Exhaust Camshaft Position (CMP) Sensor | P0368 - Camshaft Position Sensor "B" Circuit High Bank 1 | circuit high | signal voltage and crankshaft signal counter | permanently high>= 8 | [-] | 0.5 [s] continuous | 2 DCY |
|
|||
| P0367 - Camshaft Position Sensor "B" Circuit Low Bank 1 | circuit low | signal voltage and crankshaft signal counter | permanently low >= 8 | [-] | 0.5 [s] continuous | 2 DCY |
|
||||
| P0366 - Camshaft Position Sensor "B" Circuit Range/Performance Bank 1 | rationality check | signal pattern defect counter | incorrect 24 | [-] | 0.5 [s] continuous | 2 DCY |
|
||||
| Exhaust Camshaft Position (CMP) Sensor | P0017 - Crankshaft Position - Camshaft Position Correlation Bank 1 Sensor B | angular offset check | permissible deviation or permissible deviation | < -15.01> 15.01 | [°CRK] [°CRK] | camshaft adaptation engine speed | not completed > 80 | [RPM] | 8.0 [rev] multiple | 2 DCY |
|
| Exhaust Camshaft Position (CMP) Sensor | P0017 - Crankshaft Position - Camshaft Position Correlation Bank 1 Sensor B | rationality check (only once after EEPROM reset) | difference between target position vs. actual position for camshaft signals or difference between target position vs. actual position for camshaft signals | > 10.00 > 4.00 < 10.00 > 4.00 | [°CRK] [-] [°CRK] [-] | engine speed condition for empty EEPROM camshaft adaptation @ 1st start in lifetime | > 80 not finished | [RPM] | 1.0 [s] / once per lifetime | 1 DCY |
|
| Crankshaft Position (CKP) Sensor | P0321 - Ignition/Distributor Engine Speed Input Circuit Range/Performance | rationality check | counted teeth vs. reference or monitoring reference gap | > 80.00 failure | [-] | vehicle speed or engine speed or actual engine state or engine speed gradient | < 1; > 25> 500 cranking> -8000.00 | [km/h] [RPM] [RPM/s] | 8 [rev] continuous | 2 DCY |
|
| P0322 - Ignition/Distributor Engine Speed Input Circuit No Signal | signal activity check | camshaft signals and crankshaft signals | > 3.00 no signal | [-] | vehicle speed or engine speed or actual engine state or engine speed gradient | < 1; > 25> 500 cranking> -8000.00 | [km/h] [RPM] [RPM/s] | 3 [rev] continuous | 2 DCY |
|
|
| Crankshaft Position (CKP) Sensor | P0321 - Ignition/Distributor Engine Speed Input Circuit Range/Performance | rationality check: DGI sensor | PWM-signal | not plausible | DGI-sensor is powered during engine stop | 0.5 [s] continuous | 2 DCY |
|
|||
Table continues, refer to Engine/Motor Control Module --, 2021 MY