Blow-Off Valve
- Unplug electrical connector from blow-off valve. Place jumper wire across connector terminals. Turn ignition on and check that warning lamp in instrument panel lights. If not, repair electrical circuit.
- Plug in connector on blow-off valve. Using a pair of vise grip pliers, clamp hose between compressor housing and wastegate actuator.CAUTION: Engine must not be raced when pliers are installed on hose. Engine damage may result.
- On manual transmission, drive in 3rd gear. On automatic transmission, place selector in position "2". On both models, apply throttle carefully to approximately 3000 RPM while applying brakes.
- Warning lamp should light and blow-off valve should open when pressure gauge indicates 11.4-12.1 psi (.80-.85 kg/cm2 ). Do not exceed this boost pressure. Remove pliers immediately after test.